The effect of low-frequency mechanical vibration on retention in an orthodontic relapse model.

نویسندگان

  • Sumit Yadav
  • Amir Assefnia
  • Himank Gupta
  • Meenakshi Vishwanath
  • Zana Kalajzic
  • Veerasathpurush Allareddy
  • Ravindra Nanda
چکیده

OBJECTIVE To investigate the effect of low-frequency mechanical vibration (LFMV) on the prevention of relapse after active orthodontic tooth movement, bone volume fraction (BVF), tissue density, and the integrity of periodontal ligament. MATERIALS AND METHODS Thirty male CD1, 12-week-old mice were used for the study. Mice were randomly divided into three groups: 1. control group, 2. relapse group, and 3. relapse + 30 Hz vibration group. In the control group, first molar was moved mesially for 7 days using nickel-titanium coil spring delivering 10g of force, whereas in relapse and relapse + 30 Hz groups, first molar was moved mesially for 7 days and then orthodontic force was removed and molar was allowed to relapse for 7 days. In relapse + 30 Hz group, LFMVs were applied at 30 Hz. Micro-focus computed tomography (micro-CT) was used for tooth movement measurements (relapse), BVF, and tissue density. Additionally, immunostaining for sclerostin, tartrate-resistant acid phosphatase staining, and picro-sirius red staining were performed on histological sections. RESULTS LFMV at 30 Hz showed a tendency to decrease relapse but was not statistically significant. Micro-CT analysis showed a trend towards increase in BVF and tissue density with application of LFMV. Sclerostin expression was decreased with 30 Hz vibration. Additionally, the picro-sirius staining showed that LFMV at 30 Hz helped in maintaining the thickness and integrity of collagen fibres in periodontal ligament. LIMITATIONS This is an animal study and extrapolation of the current findings to the clinical situation must be done with caution, as there is no osteonal remodelling (secondary remodelling) in mice when compared to humans. CONCLUSION There was no statistically significant difference in the amount of relapse between the relapse-only and relapse + 30 Hz groups. However, there was a trend of decrease in relapse with 30 Hz mechanical vibration.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An Overview of Fixed and Removable Orthodontic Retainers

 Background and purpose: One of the main challenges in orthodontic treatment is relapse after treatment and return of the teeth to its original position. Therefore, retainers are an essential part of orthodontic treatment. Fixed and removable retainers are commonly used in orthodontic retention. They prevent relapse and require patientchr('39')s cooperation in using them. This review study aime...

متن کامل

Application of the method of multiple scales for nonlinear vibration analysis of mechanical systems with dry and lubricated clearance joints

In this study, the method of multiple scales is used to perform a nonlinear vibration analysis of a mechanical system in two cases; with dry and lubricated clearance joints. In the dry contact case, the Lankarani-Nikravesh model is used to represent the contact force between the joined bodies. The surface elasticity is modeled as a nonlinear spring-damper element. Primary resonance is discussed...

متن کامل

Bending and Free Vibration Analysis of Nonlocal Functionally Graded Nanocomposite Timoshenko Beam Model Rreinforced by SWBNNT Based on Modified Coupled Stress Theory

In this article, the bending and free vibration analysis of functionally graded (FG) nanocomposites Timoshenko beam model reinforced by single-walled boron nitride nanotube (SWBNNT) using micro-mechanical approach embedded in an elastic medium is studied. The modified coupled stress (MCST) and nonlocal elasticity theories are developed to take into account the size-dependent effect. The mechani...

متن کامل

Improving Power Density of Piezoelectric Vibration-Based Energy Scavengers

Vibration energy harvesting with piezoelectric materials currently generate up to 300 microwatts per cm2, using it to be mooted as an appropriate method of energy harvesting for powering low-power electronics. One of the important problems in bimorph piezoelectric energy harvesting is the generation of the highest power with the lowest weight. In this paper the effect of the shape and geometry ...

متن کامل

Vibration Response of an Elastically Connected Double-Smart Nanobeam-System Based Nano-Electro-Mechanical Sensor

Nonlocal vibration of double-smart nanobeam-systems (DSNBSs) under a moving nanoparticle is investigated in the present study based on Timoshenko beam model. The  two  smart  nanobeams (SNB) are  coupled  by  an  enclosing  elastic  medium  which  is  simulated  by  Pasternak foundation. The energy method and Hamilton’s principle are used to establish the equations of motion. The detailed param...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of orthodontics

دوره 38 1  شماره 

صفحات  -

تاریخ انتشار 2016