Analysis of temperature distribution in cast-resin dry-type transformers
نویسندگان
چکیده
Non-flammable characteristic of dry-type castresin transformers make them suitable for residential and hospital usages. However, because of resin’s property, thermal behavior of these transformers is undesirable, so it is important to analyze their thermal behavior. Temperature distribution of cast-resin transformers is mathematically modeled in this paper. The solution of the model was carried out successfully by finite difference method. In order to validate the model, the simulation results were compared with the experimental data measured from an 800 kVA transformer. Finally, the influences of some construction parameters and environmental conditions on temperature distribution of cast-resin transformers were discussed.
منابع مشابه
Weight Comparison of Oil and Dry Type Distribution Transformers
Abstract—Reducing the weight of transformers while providing good performance, cost reduction and increased efficiency is important. Weight is one of the most significant factors in all electrical machines, and as such, many transformer design parameters are related to weight calculations. This study presents a comparison of the weight of oil type transformers and dry type transformer weight. O...
متن کاملProperties of Polymer Composites Used in High-Voltage Applications
The present review article represents a comprehensive study on polymer micro/nanocomposites that are used in high-voltage applications. Particular focus is on the structure-property relationship of composite materials used in power engineering, by exploiting fundamental theory as well as numerical/analytical models and the influence of material design on electrical, mechanical and thermal prope...
متن کاملEstimation of Temperature Rise in MVA Range Dry - Type Transformers and Practical Verification Based on Simulated Loading
Dry-type transformer becomes the preferable choice in many applications due to its construction specific advantages over oil-cooled transformers. However, the inherent low thermal conductivity of dry-type transformers gives the rise to high operating temperatures. The temperature rise of a transformer is an important factor deciding its safe operation and the useful life span. With the increase...
متن کاملA Novel Defect Classification System of Cast-Resin Transformers by Neural Network under Acoustic Emission Signal
Degraded insulating property of electric equipments will lead to serious accident and great loss for the utilities and customers. Partial discharge detection is an efficient diagnosis method to prevent the failure of electric equipments arising from degrading insulation. However, universal offline partial discharge detection could be performed only during shutdown of equipments. By using the pr...
متن کاملFinite Element Method for Designing and Analysis of the Transformer – A Retrospective
Finite Element Analysis (FEA) using Finite Element Method (FEM) was developed over 70 years to solve the complex elasticity and structural analysis problem in civil and aeronautical engineering. Application of FEA is being expanded to simulation in electrical engineering also to solve the complex design problems. The circuit theory models for designing transformers are not much accurate in dete...