Stability of Commonly Used Antibiotics Solutions in the Accufuser

نویسندگان

  • Ga-Young Lee
  • Min-Jeong Kim
  • Mina Kang
  • Shin-Hee Kim
  • Sang-Yeon Kim
چکیده

Objectives: The stability of two kinds of solution of penicillin G potassium [PEN-K, 10K U/mL in 5% dextrose water, D5W and 50K U/mL in 0.9% sodium chloride in water, NS) into the intravenous infusion device, Accufuser ® , storage were evaluated at controlled temperature (CT, 4±2°C and RT, 25±2°C) during 6 weeks. Methods: Studies were performed using both NS (PEN-K 50K U/mL) and D5W (PEN-K 10K U/mL) injectable solutions. The resulting solutions were transferred to Accufuser ® infusion device for storage at CT or RT. Effects of period of storage (from 0 to 6 weeks) and temperature (CT and RT) on the physical appearance and concentrations of PEN-K were determined by visual clarity, pH and antibiotic concentrations by measurement with stability-indicating high-performance liquid chromatography (HPLC) method. Results: In NS (50 K U/mL) and D5W (10K U/mL) solutions, concentrations of PEN-K were slightly change and remained 94.18 and 83.42% at CT after 1 week, respectively. Otherwise, these were rapidly decreased with time and reached to 74.65 and 75.59% in NS (50K U/mL) and D5W (10K U/mL) solutions at RT after 48 h, respectively. Moderate decrement of pH was observed in cold storage and it was shown no significant changes at 6 weeks in the RT conditions. In CT, no significant changes in physical appearance or color of the solutions were observed during the study. Conclusion: Two kinds of PEN-K D5W(10K U/mL) and NS(50K U/mL) solution were shown different chemical stability with time in Accufuser ® infusion device without any significant physical change and retained about 70% of initial concentration after 48 h in RT and 80 % after 2 weeks in CT, respectively. We suggested that PEN-K solutions of 50K U/mL NS and 10K U/mL D5W in an Accufuser ® infusion device should be preferentially applicable only in CT for 48 h in clinical situations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intravenous Suitability Studies of Commonly Used Oxacillin Sodium Solutions in the ACCUFUSER® Infusion Device

Our study compares two commonly used solutions of oxacillin sodium, 5.0 mg/mL in either 0.9% sodium chloride (NS) or 5% dextrose water (D5W), for their continued suitability for IV usage, and stability of active compound over time, when stored at two different controlled temperatures for six weeks. Both solutions were stored in an intravenous infusion device commercially available as Accufuser®...

متن کامل

Stability of commonly used antibiotic solutions in an elastomeric infusion device.

BACKGROUND The Accufuser silicone-based elastomeric infusion device has recently been approved for the Canadian market. OBJECTIVE To evaluate the stability of 5 antibiotics (cefazolin, ceftazidime, ceftriaxone, clindamycin, and vancomycin) in either 5% dextrose in water (D5W) or 0.9% sodium chloride in water (NS) after storage in Accufuser disposable silicone balloon infusers. METHODS The s...

متن کامل

Stability of Nafcillin Sodium Solutions in the Accufuser® Elastomeric Infusion Device

The aim of this study was to investigate the stabilities of two kinds of solutions of nafcillin sodium (2.5 mg/mL) in 0.9% sodium chloride solution (NS, normal saline) and in injectable 5% dextrose water (D5W) in the intravenous elastomeric infusion device (Accufuser) based on recommended solutions and storage periods. The injectable nafcillin solutions (NSand D5W-nafcillin) in the Accufuser de...

متن کامل

Stability Test of Ampicillin Sodium Solutions in the Accufuser® Elastomeric Infusion Device Using HPLC: UV Method

The stabilities of two kinds of solutions (30 mg/mL) of Ampicillin sodium in 0.9% NaCl in water (NS, normal saline) and in sterile water (SW) in the intravenous elastomeric infusion device (Accufuser) were evaluated based on recommended solutions and storage periods. The injectable NSand SW-Ampicillin solutions in the Accufuser device were stored and evaluated at controlled temperature (room te...

متن کامل

Polarographic Study of the Interactions between Thallium and Lead Ions and Some Crown Ethers in 90% Acetonitrile and 90% Ethanol Solutions

The complexation reactions between Tl+ and Pb2+ ions and crown ethers 12-crown-4(12C4), 15-crown-5 (15C5), benzo-15-crown-5 (B15C5), 18-crown-6 (18C6), dicyclohexyl-18-crown-6 (DC18C6) and aza-18-crown-6 (A18C6) were studied in 90% acetonitrile and 90% ethanol solutions at 25 °C, using an a.c. polarographic technique. The stoichiometry and stability of the complexes we...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011