Digoxin-like immunoreactivity eliminated from serum by centrifugal ultrafiltration before fluorescence polarization immunoassay of digoxin.

نویسندگان

  • R H Christenson
  • S D Studenberg
  • S Beck-Davis
  • F A Sedor
چکیده

Digoxin determined in the Abbott "TDx" by fluorescence polarization immunoassay by the manufacturer's recommended method involving precipitation of protein with 5-sulfosalicylic acid (SSA) is subject to interference from endogenous compounds having digoxin-like immunoreactivity. Guided by the work of Graves et al. (Clin Chem 1986;32:1506-9), we eliminated interference caused by digoxin-like immunoreactivity by substituting ultrafiltration for precipitation with SSA to remove protein. Using the manufacturer's method, we quantified digoxin in serum from 53 patients in three clinically defined groups who were receiving no digoxin, finding apparent digoxin in excess of the 200 ng/L detection limit in 24% of the 17 pregnant women, 59% of the 17 renal-dialysis patients, and all of 19 neonatal cord-blood samples examined. No measurable digoxin immunoreactivity was observed by fluorescence polarization immunoassay for any of the 53 clinically defined patients after removal of protein by ultrafiltration. For 22 men for whom digoxin was prescribed, digoxin measurement after protein removal by SSA and by ultrafiltration correlated well (r = 0.98), with good proportionality (slope = 1.04). Analytical recovery of added digoxin from adulterated serum was 115% after SSA, but 100% after ultrafiltration. Thus, before this assay procedure, we recommend ultrafiltration, to remove digoxin-like interference.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Digoxin-like immunoreactivity in serum from neonates and infants reduced by centrifugal ultrafiltration and fluorescence polarization immunoassay.

We evaluated the TDx Digoxin II (Abbott) modified procedure for interference from digoxin-like immunoreactive factors (DLIF) in pediatric patients. The effectiveness of centrifugal ultrafiltration as a means of removing DLIF interference from the serum of such patients was assessed. We used sera from 40 patients who had not received digoxin, whom we divided into two age groups: 30 neonates (les...

متن کامل

Positive and negative interference of the Chinese medicine Chan Su in serum digoxin measurement. Elimination of interference by using a monoclonal chemiluminescent digoxin assay or monitoring free digoxin concentration.

An over-the-counter Chinese medicine, Chan Su, is used as a cardiotonic agent. We demonstrated significant digoxin-like immunoreactivity in various organic and aqueous extracts of Chan Su. For example, when a 20-microL aliquot of an aqueous extract of Chan Su powder (1 mg/mL) was added to a 2-mL aliquot of a drug-free serum, the observed digoxin-like immunoreactivity was 2.76 ng/mL (3.53 nmol/L...

متن کامل

Effect of Asian and Siberian ginseng on serum digoxin measurement by five digoxin immunoassays. Significant variation in digoxin-like immunoreactivity among commercial ginsengs.

Asian and Siberian ginsengs contain glycosides with structural similarities to digoxin. We studied potential interference of ginseng in 5 digoxin immunoassays in 3 Asian (2 liquid extracts, 1 capsule) and 3 Siberian ginseng preparations (1 liquid extract, 2 capsules). With the fluorescence polarization immunoassay (FPIA), we observed apparent digoxin activity in 1 Asian liquid preparation and i...

متن کامل

Effect of protein concentration on the determination of digoxin in serum by fluorescence polarization immunoassay.

Determination of digoxin by fluorescence polarization immunoassay (FPIA) with the Abbott "TDx" is significantly influenced by the concentration of total serum protein. Each 10 g/L increase in serum protein results in an 8% decrease in measured digoxin. Studies with [3H]digoxin confirmed that digoxin binds to the protein pellet during the trichloroacetic acid precipitation step before the immuno...

متن کامل

Endogenous digoxin-like immunoreactive factors eliminated from serum samples by hydrophobic silica-gel extraction and enzyme immunoassay.

Elimination of endogenous digoxin-like immunoreactive factors (DLIF) that interfere with accurate measurement of digoxin requires use of a highly specific anti-digoxin antibody, or that DLIF be separated from digoxin before immunoassay. Several commercial digoxin-assay kits include a step for separating serum proteins and other substances from digoxin before immunoassay. We tested six different...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 33 4  شماره 

صفحات  -

تاریخ انتشار 1987