Development of a confocal rheometer for soft and biological materials.

نویسندگان

  • S K Dutta
  • A Mbi
  • Richard C Arevalo
  • Daniel L Blair
چکیده

We discuss the design and operation of a confocal rheometer, formed by integrating an Anton Paar MCR301 stress-controlled rheometer with a Leica SP5 laser scanning confocal microscope. Combining two commercial instruments results in a system which is straightforward to assemble that preserves the performance of each component with virtually no impact on the precision of either device. The instruments are configured so that the microscope can acquire time-resolved, three-dimensional volumes of a sample whose bulk viscoelastic properties are being measured simultaneously. We describe several aspects of the design and, to demonstrate the system's capabilities, present the results of a few common measurements in the study of soft materials.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A high-frequency shear device for testing soft biological tissues.

Accurate mechanical property data obtained at large shear deformations and high frequencies are a fundamental component of realistic numerical simulations of soft tissue injury. Although many commercial systems exist for testing shear properties of viscoelastic materials with properties similar to soft biological tissue, none are capable of determining properties at high loading rates necessary...

متن کامل

Confocal soft X-ray scanning transmission microscopy: setup, alignment procedure and limitations

Zone-plate-based scanning transmission soft X-ray microspectroscopy (STXM) is a well established technique for high-contrast imaging of sufficiently transparent specimens (e.g. ultrathin biological tissues, polymer materials, archaeometric specimens or magnetic thin films) with spatial resolutions in the regime of 20 nm and high spectroscopic or chemical sensitivity. However, due to the relativ...

متن کامل

گزارش سه مورد کراتیت آکانتامبایی در یزد

Acanthamoeba keratitis is a vision- threatening infection and the most important risk factors are contact lenses Characteristic symptoms include disproportionately severe ocular pain, epithelial ulcer, ring stromal infiltrate and resistance to antimicrobial treatment. The aim is to report the first cases of Acanthamoeba keratitis in Yazd in a retrospective study confirmed on histopathological ...

متن کامل

A Comparison between β-Cyclodextrin and Chitosan as Soft Organic Materials for Surface Modification of MWCNTs

In this paper, synthesized (raw) multi-walled carbon nanotube (rMWCNTs) surfaces were modified with chitosan and β-cyclodextrin using Chen’s soft cutting technique. Raw and surface modified multi-walled carbon nanotubes were observed by transmission electron microscope (TEM). The results showed that chitosan and β-cyclodextrin could attach to the outer surface of nanotubes, wrapping the nanotub...

متن کامل

The Sphere Drag Rheometer: a New Instrument for Analysing Mud and Debris Flow Materials

The present study focused on novel rheometrical tool for the determination of the rheological behavior of large particle mixtures with particular interest in the application to granular materials involving in fast landslides as mud and debris flows. The main goal is the development of the Sphere Drag Rheometer (SDR), a home-made large-scale rheometer that allow to estimate the rheological prope...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Review of scientific instruments

دوره 84 6  شماره 

صفحات  -

تاریخ انتشار 2013