Evaluating the efficacy of intra-aortic balloon pump timing using the auto-timing mode of operation with the Datascope CS100.

نویسندگان

  • Melissa K Osentowski
  • David W Holt
چکیده

The intra-aortic balloon pump (IABP) was first introduced by Moulopoulos et al. in 1962 and was described clinically by Kantrowitz et al. in 1968. The subsequent development of the IABP has resulted in its widespread application, resulting in >70,000 applications per year, making it the most common cardiac assist device after pharmacologic intervention. The correct timing of the inflation and deflation of this device is critical to it being clinically advantageous to the patient. The purpose of this study was primarily to examine the Datascope CS100 automated timing of inflation and deflation, and secondarily, to create an awareness of the risks of solely relying on technology for patient treatment decisions in lieu of clinical evaluative skills. Timing data were collected from 165 IABP patients from January 1, 2003 to March 31, 2005 using the Datascope series System 97, System 98, and CS100 IABP consoles. Timing criteria used in the evaluation of the IABP in this study included proper inflation, defined as inflation at the dicrotic notch of arterial pressure waveform, and proper deflation, resulting in a presystolic decrease of diastolic pressure by 5-10 mmHg. These parameters were evaluated by examining a printed strip from the IABP console after timing selection stabilization. Before implementation of the CS100, 78.6% of inflations and 53.6% of deflations were correct when using the criteria listed above. After implementation of the CS100, 83.3% of inflations were correct and 44.4% of deflations were correct. Although improvement in consistency of IABP inflation quality was observed, a net decrease in the quality of IABP deflations was also observed. Total reliance on the autotiming operation mode of the CS100 may not be warranted, and imposing clinical judgment in therapeutic application is necessary to avoid dangerous timing errors. An awareness of the dangers of solely relying on technology for patient treatment decisions vs. the use of technology combined with clinical evaluative skills for assessing therapeutic intervention to improve patient care is discussed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Innovations in intra-aortic balloon pump management: computer modem technology.

The computer modem technology being developed by Datascope Corporation for the purpose of off-site intra-aortic balloon pump (IABP) monitoring was clinically evaluated in 30 patients requiring IABP support. The Datascope System 95 model IABP with built-in modem was used on all patients. Remote communications via a personal computer with modem were conducted under both routine and emergency sett...

متن کامل

The Evaluation of Survival in Patients Who Need Intra Aortic Balloon Pump (IABP) after Cardiac Surgery

Introduction: Insome cases, assist devices are required to ensure an adequate cardiac output after cardiac surgery. Intra-aortic balloon pump (IABP) is the most commonly used cardiac assist device, which provides first-line support for patients with heart failure. The aim of this study was to determine factors affecting the mortality rate of patients receiving IABP. Materials & Methods:  In thi...

متن کامل

Biventricular pacing in conjunction with epicardial atrial pacing adversely affects timing of intra-aortic balloon pump.

A case of accidental triggering of an intra-aortic balloon pump during systole is presented. The patient had a cardiac resynchronization therapy device in place preoperatively for heart failure. A temporary epicardial atrial pacing wire was used during separation from cardiopulmonary bypass for rate control. An intra-aortic balloon pump was necessary for separation from bypass. Although the pac...

متن کامل

Experimental Investigation on Hydrous Methanol Fueled HCCI Engine Using Spark Assisted Method

The present work investigates the performance and emission characteristics of hydrous methanol fuelled Homogeneous Charge Compression Ignition (HCCI) engine. In the present work a regular diesel engine has been modified to work as HCCI engine. Hydrous methanol is used with 15% water content in this HCCI engine and its performance and emission behavior is documented. A spark plug is used for ass...

متن کامل

Reversed intracranial blood flow in patients with an intra-aortic balloon pump.

As a preliminary investigation into the cerebral effects of mechanical cardiac assist devices, using transcranial Doppler ultrasonography I examined the basal cerebral arteries in three patients placed on an intra-aortic balloon pump. Unassisted systoles had normal blood velocities and waveforms. When the pump was in use, diastolic blood velocity during balloon inflation increased. As the ballo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The journal of extra-corporeal technology

دوره 39 2  شماره 

صفحات  -

تاریخ انتشار 2007