A noncontact measurement technique for the density and thermal expansion coefficient of solid and liquid materials

نویسندگان

  • Sang K. Chung
  • David B. Thiessen
  • Won-Kyu Rhim
چکیده

A noncontact measurement technique for the density and the thermal expansion coefficient of refractory materials in their molten as well as solid phases is presented. This technique is based on the video image processing of a levitated sample. Experiments were performed using the high-temperature electrostatic levitator ~HTESL! at the Jet Propulsion Laboratory in which 2–3 mm diam samples can be levitated, melted, and radiatively cooled in vacuum. Due to the axisymmetric nature of the molten samples when levitated in the HTESL, a rather simple digital image analysis can be employed to accurately measure the volumetric change as a function of temperature. Density and the thermal expansion coefficient measurements were made on a pure nickel sample to test the accuracy of the technique in the temperature range of 1045–1565 °C. The result for the liquid phase density can be expressed by r58.8481(6.730310)3T ~°C! g/cm within 0.8% accuracy, and the corresponding thermal expansion coefficient can be expressed by b5(9.419310) 2(7.165310)3T ~°C! K within 0.2% accuracy. © 1996 American Institute of Physics. @S0034-6748~96!02609-3#

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A non contact measurement technique for the density and the thermal expansion coefficient of solid and liquid materials

A B S T R A C T A non contact measurement technique for the density and the thermal expansion coefficient of undercooked and superheated materials as well as the solid materials is presented. The experiments were performed using the high-temperature high-vacuum electrostatic levitator (HTHVESL) at JPL in which 2-3 mm diameter samples can be levitated, melted using a focused xenon lamp, and radi...

متن کامل

Evaluation of Heterogeneous Densification, Anisotropic Shrinkage and Rheological Behavior of Ceramic Materials during Liquid Phase Sintering by Numerical-Experimental Procedure

The effective shear and bulk viscosity, as well as dynamic viscosity, describe the rheological properties of the ceramic body during the liquid phase sintering process. The rheological parameters depend on the physical and thermo-mechanical characteristics of the material such as relative density, temperature, grain size, diffusion coefficient, and activation energy. Thermal behavior of the cer...

متن کامل

Measurement of Selected Thermophysical and Viscosity of Binary Mixtures of Nitromethane with 2-Propanol, 2-Butanol and 2-Pentanol

The density and viscosity values at T= (293.15 to 323.15) K for binary mixtures of nitromethane with 2-propanol, 2-butanol and 2-pentanol were measured over the entire composition range. From the experimental data, excess molar volumes, thermal expansion coefficients, excess thermal expansions, partial molar volumes at infinite dilution and deviations in viscosity were calculated. The results w...

متن کامل

Sensitive Simultaneous Measurement of Metformin and Linagliptin in Plasma Samples by Couple of Nano Graphene Oxide-based Dispersive Solid Phase Extraction Method and Liquid Chromatography

A simple, rapid, and ultra sensitive dispersive solid phase extraction based on nano graphene oxide was developed for simultaneous measurement of trace amounts of metformin (MET) and linagliptin (LIN) in plasma samples by HPLC-UV-Vis. Affecting factors on the extraction of these drugs, including adsorbent weight, extraction time, organic solvent type, desorption situations, and composition of s...

متن کامل

Sensitive Simultaneous Measurement of Metformin and Linagliptin in Plasma Samples by Couple of Nano Graphene Oxide-based Dispersive Solid Phase Extraction Method and Liquid Chromatography

A simple, rapid, and ultra sensitive dispersive solid phase extraction based on nano graphene oxide was developed for simultaneous measurement of trace amounts of metformin (MET) and linagliptin (LIN) in plasma samples by HPLC-UV-Vis. Affecting factors on the extraction of these drugs, including adsorbent weight, extraction time, organic solvent type, desorption situations, and composition of s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1996