Evaluating the Procedure for Performing Awake Cystometry in a Mouse Model.

نویسندگان

  • Travis K Mann-Gow
  • Troy R Larson
  • Chrissie T Wøien
  • Thomas M Andersen
  • Karl-Erik Andersson
  • Peter Zvara
چکیده

Awake filling cystometry has been used for a long time to evaluate bladder function in freely moving mice, however, the specific methods used, vary among laboratories. The goal of this study was to describe the microsurgical procedure used to implant an intravesical tube and the experimental technique for recording urinary bladder pressure in an awake, freely moving mouse. In addition, experimental data is presented to show how surgery, as well as tubing type and size, affect lower urinary tract function and recording sensitivity. The effect of tube diameter on pressure recording was assessed in both polyethylene and polyurethane tubing with different internal diameters. Subsequently, the best performing tube from both materials was surgically implanted into the dome of the urinary bladder of male C57BL/6 mice. Twelve-hour, overnight micturition frequency was recorded in healthy, intact animals and animals 2, 3, 5, and 7 days post-surgery. At harvest, bladders were assessed for signs of swelling using gross observation and were subsequently processed for pathological analysis. The greatest extent of bladder swelling was observed on day 2 and 3, which correlated with behavioral voiding data showing significantly impaired bladder function. By day 5, bladder histology and voiding frequency had normalized. Based on the literature and evidence provided by our studies, we propose the following steps for in vivo recording of intravesical pressure and voided volume in an awake mouse: 1) Perform the surgery using an operating microscope and microsurgical tools, 2) Use polyethylene-10 tubing to minimize movement artifacts, and 3) Perform cystometry on post-operative day 5, when bladder swelling resolves.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Measurement of Intra-abdominal Pressure in Awake Rat Cystometry

The history of animal cystometry revolves around the desire for specification of the lower urinary tract functions as a dynamic reservoir. However, in animal models, the functional significance of intra-abdominal pressure (IAP) in urodynamics have not been well-studied. The measurement of IAP and its interpretation are essential for evaluating the bladder functions. In addition, the IAP is a ke...

متن کامل

The Role of Intra-abdominal Pressure Measurement in Awake Rat Cystometry

Rat cystometry is increasingly being used in research on overactive bladder and is a research tool for investigating bladder functions during the storage and voiding phases. Measurement of the pressure in the bladder is an essential part of cystometry, although that pressure is the sum of both detrusor and intra-abdominal pressures. In anesthetic cystometry, measurement of the intra-abdominal p...

متن کامل

Flow Starting Point and Voiding Mechanisms Measured by Simultaneous Registrations of Intravesical, Intra-abdominal, and Intraurethral Pressures in Awake Rats

PURPOSE The aim of this study was to apply a new surgical procedure that allows for the successful monitoring of intraurethral pressure (IUP) changes in the cystometry of awake Sprague-Dawley rats. METHODS Twenty-six female Sprague-Dawley rats were grouped according to the catheterization method (bladder only; bladder and urethra; or bladder, urethra, and abdomen). Using an arbitrarily determ...

متن کامل

Evaluating Muscle Activity During Work With Trackball, Trackpad, Slanted, and Standard Mice

Objectives: Mouse is one of the most important data entry devices for computers. Undesirable and prolonged postures during work with the computer mouse increase workload, muscle aches and upper extremity musculoskeletal disorders. The present study aimed to evaluate and compare muscle activity during the use of 4 types of mouse, including trackball, trackpad, slanted and standard by Electromyog...

متن کامل

Combination of bladder ultrasonography and novel cystometry method in mice reveals rapid decrease in bladder capacity and compliance in LPS-induced cystitis.

Various animal models have been used in research into bladder dysfunction, and in vivo cystometry is a common method to analyze bladder function in animals. However, it is rather difficult to perform reliably in small animals. Transabdominal bladder ultrasonography combined with cystometry in urethane-anesthetized mice have revealed physical inhibition of bladder wall movement by a bladder cath...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of visualized experiments : JoVE

دوره 123  شماره 

صفحات  -

تاریخ انتشار 2017