Impulsive Noise Environment of High Voltage Electricity Transmission Substations and its Impact of the Performance of ZigBee

نویسندگان

  • Qingshan Shan
  • I A Glover
  • P J Moore
  • M Judd
چکیده

A measurement system for the characterisation of impulsive noise at frequencies above 700 MHz is presented. The system consists of a pair of ultra-wideband (UWB) quasi-TEM horn antennas, a digital storage oscilloscope and an external hard disk. The particular application of interest is the recording of partial discharge and radiation arising from switching/fault transients in high-voltage electricity transmission substations. A preliminary assessment of the impact of such substation noise on the performance of ZigBee equipment is also described. The results, based on more than 200 MB of transmitted data, suggest that the substation electromagnetic environment has no significant adverse impact on performance.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measurement of the Magnetic Fields from High-Voltage (230 kV) Substations in Tehran and Assessment of Their Effects

Introduction: Recent industrial developments in human societies have caused rapid advancements in technologies of production and distribution of electricity, which in turn result in enhancement of power networks and utilization of high voltages. These networks and the high voltages in transfer lines cause the exposure to electric and magnetic fields. In this study, the situation regarding the m...

متن کامل

Impacts of impulsive noise from partial discharges on wireless systems performance: application to MIMO precoders

To satisfy the smart grid electrical network, communication systems in high-voltage substations have to be installed in order to control equipments. Considering that those substations were not necessarily designed for adding communication networks, one of the most appropriate solutions is to use wireless sensor network (WSN). However, the high voltage transported through the station generates a...

متن کامل

Low Voltage Ride-Through Capability Improvement of Doubly Fed Induction Generator using DVR and SMES

Abstract: With the growth of communities and the increasing need for electricity, and because of the many benefits of renewable energy sources, the wind turbine has become a completely commercial and inevitable process, with increasing penetration into the electricity grid. Distribution networks, on the other hand, are subject to fault that cause power fluctuations and outflow of wind units. In...

متن کامل

Detection of Ultra-wide-band Impulsive Noise in a 400 Kv Air Insulated Electricity Substation

A measurement campaign has been carried out in 400kV air insulated electricity substation to characterise and model radio frequency impulsive noise with a view to assessing its impact on wireless network technologies. The relatively recent availability of new technologies such as WiFi, Bluetooth and Zigbee means that particular emphasis has been put on higher frequency bands (e.g. 2.4, 5 GHz) t...

متن کامل

Digital Distance Relaying

Increasing interest is being shown in the use of microprocessor for protection, switching and data acquisition required in modern high voltage substations. One of the most difficult functions to fulfill is that of transmission line distance protection employing samples of the voltage and current waveform taken from high voltage transducer equipment at the usual relaying point. This paper examin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008