Radiographic Vertical Bone Loss Evaluation around Dental Implants Following One Year of Functional Loading

نویسندگان

  • AAR. Rasouli Ghahroudi
  • AR Talaeepour
  • A. Mesgarzadeh
  • AR. Rokn
  • A. Khorsand
  • NN. Mesgarzadeh
  • MJ. Kharazi Fard
چکیده

OBJECTIVE Vertical bone loss evaluations in the Nobel Biocare Replace(®) Select Tapered (™) implant system in the human after one-year loading time. MATERIALS AND METHODS This retrospective cross-sectional study was performed on 31 patients (14 men, 17 women; mean age, 60.39 years) receiving 170 implants (mean, 5.48 for each patient) of Groovy and Non-groovy designs in the Nobel Biocare Replace(®) Select Tapered (™) system. The marginal bone loss was measured at mesial and distal aspects of the implants on OPG x-rays after one-year follow-up. The data regarding the patient's gender, age, history of disease, smoking, bone type at implant location, loading time of prosthesis and implant, implant design, diameter and length were recorded by the patients' records and interview. The data were subjected to multiple linear regression and Pearson coefficient ratio regarding different factors. RESULTS The mean (standard deviation) distal, mesial and overall bone loss was 0.688 mm (0.851), 0.665 mm (0.849) and 0.935 mm (0.905), respectively in the studied implants. No significant differences were found regarding implant location, bone quality at the implant region, implant design and bone graft reception. In addition, no significant correlation was found between the occurred bone loss and implant diameter, length and number of used splints. CONCLUSION Due to the criteria mentioned for implant success in term of bone loss values after one-year loading time, Noble Biocare Replace(®) Select Tapered (™) implant system is an acceptable treatment option for implant restorations in this regard.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Radiographic Comparison of Crestal Bone Loss Around Two Implant Systems with Different Surface Roughness: A Retrospective Study

Background and Aim: This retrospective study aimed to investigate the effects of surface roughness and implant body design on the amount of crestal bone loss around implant. Materials and Methods: In this retrospective study, dental records of 87 patients who received 139 implants were evaluated. The ITI group received 63 implants with moderate roughness, while the DIO group received 76 implan...

متن کامل

Clinical Parameters and Crestal Bone Loss in Internal Versus External Hex Implants at One Year after Loading

Introduction: The survival of an implant system is affected by the choice of antirotational design, which can include an external or internal hex. Implant success also is affected by the maintenance of the crestal bone around implants. The aim of present study was to evaluate the crestal bone loss and clinical parameters related to bone loss in patients loaded with an external or internal hex 3...

متن کامل

Radiographic Evaluation of Marginal Bone Loss Following Immediate and Delayed Implantation

Background and Aim: Intraosseous implants can be placed using three different techniques: immediate, early, and delayed. The aim of this study was to compare the changes in the marginal bone level around implants after immediate and delayed im-plant placement. Materials and Methods: In the present prospective cohort study, 26 implants were placed in 26 patients divided into two groups. In grou...

متن کامل

Matched and Platform-Switched Implants - A Prospective Study

of the effect of platform-switching on marginal bone loss (MBL) around dental implants. Forty patients requiring a dental implant in non-grafted partially edentulous mandibles were enrolled and categorized into implants receiving a platform-matched abutment (control group) or implants with a platform-switched abutment (test group). Standardized digital periapical radiographs were taken at the t...

متن کامل

ارزیابی کارایی ایمپلنت‌های دندانی plus Swiss با استفاده از معیارهای کلینیکی و رادیوگرافیک

  Introduction: Swiss plus dental implant is one of the many different implant systems that have been proposed recently. The aim of this study was to evaluate survival rate of Swiss plus dental implants and surrounding soft and hard tissue based clinical and radiographic parameters.   Materials & Methods: In a post perspective observational descriptive study, 106 patients (47 women and 59 men) ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2010