Thermal Strains Wearing Aluminized Firefighters’ Clothing
نویسندگان
چکیده
This study examined the influences of aluminized (Type A) and non-aluminized firefighters’ protective clothing (Type B, C, D and CON) on physiological and subjective responses in radiant heat. Total clothing weight was 6.24, 6.38, 6.06, 5.76 and 3.82 kg for Type A, B, C, D and CON, respectively. Eight firefighters performed exercise at an air temperature of 30°C with 50%RH. Three bouts of 10 min-bicycle exercise in radiant heat (a globe temperature of 70°C) was spaced by a 10 min rest with no radiant heat. Results showed that rectal temperature, mean skin temperature, heart rate, and body weight loss were significantly greater in Type A than in other types (p<0.05). For Type A, thermal gradient of the body reached 0.0 ± 0.7°C, heart rate showed a maximum level of 183 ± 11 bpm and 1.9% of body weight was lost due to sweat secretion. Firefighters felt the hottest and most discomfort in Type A. It appeared that firefighters’ thermoregulatory mechanism was severely challenged by wearing aluminized protective clothing during exercise in strong radiant heat. Therefore, it is suggested that the safe upper limits while wearing aluminized firefighters’ clothing should be distinguished from those for typical firefighters’ protective clothing.
منابع مشابه
Maximum allowable exposure to different heat radiation levels in three types of heat protective clothing
To determine safe working conditions in emergency situations at petro-chemical plants in the Netherlands a study was performed on three protective clothing combinations (operator's, firefighter's and aluminized). The clothing was evaluated at four different heat radiation levels (3.0, 4.6, 6.3 and 10.0 k∙W∙m-2) in standing and walking posture with a thermal manikin RadMan™. Time till pain thres...
متن کاملOccupational stress and strain in relation to personal protective equipment of Japanese firefighters assessed by a questionnaire.
The purpose of the present study was to elucidate differences in actual work environments, mobility and satisfaction between firefighters wearing aluminized and non-aluminized personal protective equipment (PPE), and to suggest a proper standard test method for Japanese firefighters' PPE. A survey from two cities in Japan (City A: aluminized PPE; City B: non aluminized PPE) was undertaken. A to...
متن کاملPhysiologic Response to Transient Heat Stress in Reflective versus Non-reflective Clothing.
Six subjects wearing either nonreflective or reflective outer garments of equal insulative value (I clo) and unventilated were exposed in 96 experiments to heat pulses of 930, 1210, 1490, and 1770 C for 15, 12, 9, and 2 minutes, respectively. The experiments were designed to simulate a range of re-entry heat exposures produced by malfunction or failure of the air-conditioning system of the vehi...
متن کاملA Study on Total Heat Loss of Clothing Materials for Firefighters’ Protective Clothing
Clothing is often made of materials that impede the flow of heat and moisture from the skin to the environment. Consequently, people may suffer from heat stress or cold stress when wearing clothing in different environmental conditions. Therefore it is important to quantify the thermal resistance and evaporative resistance of clothing materials and to consider these properties when selecting ma...
متن کاملThermal strain in fire fighters while wearing task-fitted versus en 469:2005 protective clothing during a prolonged rescue drill.
Fire fighters are normally overprotected during their working hours because of the tendency to keep the personal protection level sufficiently high in case of the worst possible scenarios. This study investigated the effects of task-fitted protective clothing on thermal strain in fire fighters as compared to EN 469:2005 protective clothing during a prolonged (2 1/2 hrs) job-related rescue drill...