Detection of prostate cancer by integration of line-scan diffusion, T2-mapping and T2-weighted magnetic resonance imaging; a multichannel statistical classifier.

نویسندگان

  • Ian Chan
  • William Wells
  • Robert V Mulkern
  • Steven Haker
  • Jianqing Zhang
  • Kelly H Zou
  • Stephan E Maier
  • Clare M C Tempany
چکیده

A multichannel statistical classifier for detecting prostate cancer was developed and validated by combining information from three different magnetic resonance (MR) methodologies: T2-weighted, T2-mapping, and line scan diffusion imaging (LSDI). From these MR sequences, four different sets of image intensities were obtained: T2-weighted (T2W) from T2-weighted imaging, Apparent Diffusion Coefficient (ADC) from LSDI, and proton density (PD) and T2 (T2 Map) from T2-mapping imaging. Manually segmented tumor labels from a radiologist, which were validated by biopsy results, served as tumor "ground truth." Textural features were extracted from the images using co-occurrence matrix (CM) and discrete cosine transform (DCT). Anatomical location of voxels was described by a cylindrical coordinate system. A statistical jack-knife approach was used to evaluate our classifiers. Single-channel maximum likelihood (ML) classifiers were based on 1 of the 4 basic image intensities. Our multichannel classifiers: support vector machine (SVM) and Fisher linear discriminant (FLD), utilized five different sets of derived features. Each classifier generated a summary statistical map that indicated tumor likelihood in the peripheral zone (PZ) of the prostate gland. To assess classifier accuracy, the average areas under the receiver operator characteristic (ROC) curves over all subjects were compared. Our best FLD classifier achieved an average ROC area of 0.839(+/-0.064), and our best SVM classifier achieved an average ROC area of 0.761(+/-0.043). The T2W ML classifier, our best single-channel classifier, only achieved an average ROC area of 0.599(+/-0.146). Compared to the best single-channel ML classifier, our best multichannel FLD and SVM classifiers have statistically superior ROC performance (P=0.0003 and 0.0017, respectively) from pairwise two-sided t-test. By integrating the information from multiple images and capturing the textural and anatomical features in tumor areas, summary statistical maps can potentially aid in image-guided prostate biopsy and assist in guiding and controlling delivery of localized therapy under image guidance.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Integrating Structural and Functional Imaging for Computer Assisted Detection of Prostate Cancer on Multi-Protocol In Vivo 3 Tesla MRI.

Screening and detection of prostate cancer (CaP) currently lacks an image-based protocol which is reflected in the high false negative rates currently associated with blinded sextant biopsies. Multi-protocol magnetic resonance imaging (MRI) offers high resolution functional and structural data about internal body structures (such as the prostate). In this paper we present a novel comprehensive ...

متن کامل

Detection of Prostate Cancer using Multi-parametric Magnetic Resonance

A multi-channel statistical classifier to detect prostate cancer was developed by combining information from 3 different MR methodologies: T2-weighted, T2-mapping, and Line Scan Diffusion lmaging(LSDI). From these MR sequences, 4 sets of image intensities were obtained: T2-weighted(T2W) from T2-weighted imaging, Apparent Diffusion Coefficient(ADC) from LSDI, and Proton Density (PD) and T2 (T2Ma...

متن کامل

Signal Intensity of High B-value Diffusion-weighted Imaging for the Detection of Prostate Cancer

Background: Diffusion-weighted imaging (DWI) is a main component of multiparametric MRI for prostate cancer detection. Recently, high b value DWI has gained more attention because of its capability for tumor characterization. Objective: To assess based on histopathological findings of transrectal ultrasound (TRUS)-guided prostate biopsy as a reference, an...

متن کامل

Magnetic resonance imaging of feline eye

The purpose of this study was to investigate magnetic resonance imaging (MRI) of the normal feline eyeand optic nerves using T1-weighted and T2-weighted images. A total of 6 healthy female domestic short haircats age 2-2.5 years and weighing 3.2 ± 0.4 kg were selected. Magnetic resonance imaging data werecollected using GEMSOW (Philips) at a magnetic field strength of 1.5 T. Dorsal, sagittal, a...

متن کامل

Prostate cancer: apparent diffusion coefficient map with T2-weighted images for detection--a multireader study.

PURPOSE To retrospectively assess the incremental value of an apparent diffusion coefficient (ADC) map combined with T2-weighted magnetic resonance (MR) images compared with T2-weighted images alone for prostate cancer detection by using a pathologic map as the reference standard. MATERIALS AND METHODS This retrospective study was approved by the institutional review board; informed consent w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 30 9  شماره 

صفحات  -

تاریخ انتشار 2003