Assessment and management of radiotherapy beam intersections with the treatment couch

نویسندگان

  • Monique van Prooijen
  • Thilakshan Kanesalingam
  • Mohammad K. Islam
  • Robert K. Heaton
چکیده

The impact of the treatment couch on a radiotherapy plan is rarely fully assessed during the treatment planning process. Incorporating a couch model into the treatment planning system (TPS) enables the planner to avoid or dosimetrically evaluate beam-couch intersections. In this work, we demonstrate how existing TPS tools can be used to establish this capability and assess the accuracy and effectiveness of the system through dose measurements and planning studies. Such capabilities may be particularly relevant for the planning of arc therapies.Treatment couch top models were introduced into a TPS by fusing their CT image sets with the patient CT dataset. Regions of interest characterizing couch elements were then imported and assigned appropriate densities in the TPS. Measurements in phantom agreed with TPS calculations to within 2% dose and 1 degrees gantry rotation. To clinically validate the model, a retrospective study was performed on patient plans that posed difficulties in beam-couch intersection during setup. Beam-couch intersection caused up to a 3% reduction in PTV coverage, defined by the 95% of the prescribed dose, and up to a 1% reduction in mean CTV coverage. Dose compensation strategies for IMRT treatments with beams passing through couch elements were investigated using a four-field IMRT plan with three beams passing through couch elements. In this study, ignoring couch effects resulted in point dose reductions of 8 +/- 3%.A methodology for incorporating detailed couch characteristics into a TPS has been established and explored. The method can be used to predict beam-couch intersections during planning, potentially eliminating the need for pretreatment appointments. Alternatively, if a beam-couch intersection problem arises, the impact of the couch can be assessed on a case-by-case basis and a clinical decision made based on full dosimetric information.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quantification and modelling of the dosimetric impact of the treatment couch in volumetric modulated arc therapy (VMAT)

Background: As the volumetric modulated arc therapy (VMAT) becoming a main role of treatment ways, the effect of couch top becomes more significant. It is imperative to re-evaluate the couches that previously may have been considered of no importance during early treatment techniques. The impact of couch top on radiation delivery was explored and the couch model was tested with the aim of reduc...

متن کامل

An Update of Couch Effect on the Attenuation of Megavoltage Radiotherapy Beam and the Variation of Absorbed Dose in the Build-up Region

Purpose: Fiber carbon is the most common material used in treating couch as it causes less beam attenuation than other materials. Beam attenuation replaces build-up region, reduces skin-sparing effect and causes target volume under dosage. In this study, we aimed to evaluate beam attenuation and variation of build-up region in 550 TxT radiotherapy couch.Materials and Methods: In this study, we ...

متن کامل

Treatment couch positioning uncertainties using an EPID-based method

Introduction: The accuracy of patient positioning plays an important role for radiotherapy tasks. Short and automated Quality Assurance (QA) programs are becoming one of the challenging tasks in Radiotherapy. The current study, investigates the accuracy of treatment couch positioning with four degrees of freedom (4DoF) using a fast and accurate method based on an image acquired...

متن کامل

Comparison of different TBI techniques in terms of dose homogeneity

Introduction: Total body irradiation (TBI) is a form of external beam radiotherapy which is used in conjunction with chemotherapy with the purpose of immunosuppression. Since the target in TBI is the whole body so a uniform dose distribution throughout the entire body during TBI is necessary. As recommended by AAPM dose variation must be within ±10% of prescription dose. A revi...

متن کامل

Dosimetric Effects of Rotational Setup Error in Volumetric Modulated Arc Radiotherapy on Brain Tumor Patients

Introduction: This study examined the dosimetric effects based on the rotational setup error to correct patient setup errors occur during volumetric modulated arc radiotherapy (VMAT) for brain tumor patients. Material and Methods: This study included 1129 cases of cone beam computed tomography (CBCT) images obtained from 46 brain tumor patients, who experienced VMAT and used the 6DoF (degree o...

متن کامل