Corneal astigmatism, high order aberrations, and optical quality after cataract surgery: microincision versus small incision.

نویسندگان

  • Ke Yao
  • Xiajing Tang
  • Panpan Ye
چکیده

PURPOSE To compare the astigmatism, high order aberrations, and optical quality of the cornea after microincision (approximately 1.7 mm) versus small incision approximately 3.2 mm) cataract surgery at Eye Center, Zhejiang University, Hangzhou, China. METHODS This prospective, randomized clinical study included microincision cataract surgery and small incision cataract surgery performed on 60 eyes. Corneal astigmatism and higher order aberrations to the sixth order were measured using the NIDEK OPD-Scan aberrometer/topographer 1 month after surgery. To evaluate the optical quality of the cornea, the 0.5 modulation transfer function (MTF) value and 0.1 MTF value within a 5-mm pupil were calculated using OPD-Station software. Statistical analysis assessing the difference between groups was carried out using the independent t test. RESULTS The mean corneal astigmatism was significantly lower after microincision cataract surgery compared with small incision cataract surgery (0.78+/-0.38 diopters [D] vs 1.29+/-0.68 D, respectively; P=.001). No significant differences were found between the two groups for the root-mean-square value of total high order aberrations or individual high order aberrations for spherical aberration, coma, and trefoil. However, eyes that underwent microincision cataract surgery showed statistically significantly better optical performance with a 0.5 MTF value than eyes that underwent small incision cataract surgery (3.13+/-0.30 cycles per degree [cpd] vs 2.75+/-0.63 cpd, respectively; P=.005). The 0.1 MTF values for the two groups were 9.37+/-3.72 cpd for microincision cataract surgery and 7.24+/-3.43 cpd for small incision cataract surgery, which was not significantly different (P=.136). CONCLUSIONS Microincision cataract surgery generates statistically significantly less corneal astigmatism and better optical quality of the cornea by MTF evaluation compared with small incision cataract surgery. However, microincision cataract surgery shows no significant advantage in reducing corneal high order aberrations over small incision cataract surgery.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intraindividual comparative study of corneal and ocular wavefront aberrations after biaxial microincision versus coaxial small-incision cataract surgery.

AIM To compare the optical outcomes of biaxial microincision cataract surgery (B-MICS) versus coaxial small-incision cataract surgery (C-SICS). METHODS Thirty patients (sixty eyes) with bilateral age-related cataract underwent B-MICS through a 1.7 mm clear corneal incision (CCI) in one eye and C-SICS through a 2.8-mm CCI in the other eye. Every eye was implanted with a micro-incision aspheric...

متن کامل

Corneal aberrations before and after small-incision cataract surgery.

PURPOSE To study the effect of small-incision cataract surgery on the optical aberrations of the cornea. METHODS Corneal topography was measured before and after cataract surgery on 70 eyes of 70 patients. Monofocal foldable IOLs were implanted after phacoemulsification through a clear-cornea, 3.5-mm incision without suture. Corneal aberrations, up to the fifth order and 6-mm pupil, were calc...

متن کامل

Comparison of corneal aberrations after biaxial microincision and microcoaxial cataract surgeries: a prospective study.

PURPOSE To compare the effects of biaxial microincision cataract surgery (B-MICS) and microcoaxial cataract surgery (C-MICS) techniques on corneal optical quality. MATERIALS AND METHODS In this prospective study, 40 eyes underwent B-MICS and 40 eyes C-MICS. Corneal aberrations were derived from conversion of the corneal elevation profile into corneal wavefront data with 6.0  mm aperture diame...

متن کامل

Aspheric microincision intraocular lens implantation with biaxial microincision cataract surgery: efficacy and reliability.

PURPOSE To evaluate the efficacy and reliability of a microincision intraocular lens (IOL) and its use in biaxial microincision cataract surgery (MICS). SETTING Atatürk Training and Research Hospital, Ankara, Turkey. DESIGN Prospective clinical study. METHODS A microincision IOL (Akreos MI60) was implanted after cataract extraction by the biaxial MICS technique. Over a postoperative follo...

متن کامل

Effect of Corneal Incision Enlargement on Surgically Induced Astigmatism in Biaxial Microincision Cataract Surgery

OBJECTIVES To evaluate surgically induced astigmatism (SIA) in biaxial microincision cataract surgery with enlargement of one corneal incision during intraocular lens implantation (IOL). MATERIALS AND METHODS Data from 683 eyes with cataract that underwent biaxial microincision cataract surgery and IOL were retrospectively analyzed. The operated eyes were divided into 4 groups defined by fina...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of refractive surgery

دوره 22 9 Suppl  شماره 

صفحات  -

تاریخ انتشار 2006