The ability to identify yeast isolates by the new enzymatic RapID Yeast Plus System was compared to the ability to identify yeast isolates by the API 20C system. A total of 447 yeast isolates representing Blastoschizomyces capitatus, 17 Candida spp., 5 Cryptococcus spp., Geotrichum spp., 2 Hanseniaspora spp., Hansenula anomala, Hansenula wingei, 3 Rhodotorula spp., Saccharomyces cerevisiae, Sporobolomyces salmonicolor, Trichosporon beigelii, and 2 Prototheca spp. were evaluated. Also, five quality control strains (Candida spp. and Cryptococcus laurentii) with well-documented reactivities by the RapID Yeast Plus System were used. Each isolate was evaluated by both methods with a 48-h culture grown at 30 degrees C on Sabouraud dextrose agar (Emmons modification) by following the recommendations of the manufacturers. The RapID Yeast Plus System enzymatic reactions were read after 4 h of incubation, and the API 20C carbohydrate assimilation identification profiles were obtained after 72 h of incubation. There was good (95.7%) agreement between the identifications obtained by the two methods with the eight common Candida spp. and with Cryptococcus neoformans. The agreement was lower when the emerging Candida spp. and other yeast-like pathogens were tested (79.1 and 75.2%, respectively). These preliminary data suggest the potential utility of the RapID Yeast Plus System for use in the clinical laboratory for the rapid identification of common yeast pathogens as well as certain new and emerging species.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Enzymatic Method Rapid Yeast Plus System with RFLP-PCR for Identification of Isolated Yeast from Vulvovaginal Candidiasis

Objective(s) To compare two identification methods, i.e., restriction fragment length polymorphism (RFLP)-PCR analysis and enzymatic method Rapid TM Yeast Plus System to identify different species causing vulvovaginal candidiasis (VVC). Materials and Methods Vaginal discharges of women who had attended the gynecology outpatient clinic of Mobini Hospital in Sabzevar, Iran were collected using...

متن کامل

Validation of Integral System Yeast Plus for rapid identification and determination of antifungal susceptibility profile of clinically important Candida species

Precise identification of microorganisms involved in candidiasis together with antifungal susceptibility evaluation could help clinicians to prescribe appropriate medicine, especially in patients with critical conditions. The present study has been conducted to evaluate discriminatory power of Integral System Yeast Plus (ISYP) for rapid identification and determination of antifungal susceptibil...

متن کامل

Evaluation of the AUXACOLOR system, a new method of clinical yeast identification.

AIMS To compare the AUXACOLOR yeast identification system with the API 20C system. METHODS Yeast isolates (n = 215), comprising 16 species, were identified using the AUXACOLOR system and the API 20C system. Isolates that could not be identified with the API 20C system or which produced discrepant results in the two systems were identified by assimilation and fermentation procedures. RESULTS...

متن کامل

Comparative performance of the RapID Yeast Plus System and the API 20C AUX Clinical Yeast System.

The performance of the RapID Yeast Plus System (Innovative Diagnostic Systems, Norcross, Ga.), a 4-h micropanel using single-substrate enzymatic test reactions, was compared with that of the API 20C AUX Clinical Yeast System (bioMerieux Vitek, Hazelwood, Mo.), a 48- to 72-h carbohydrate assimilation panel. Two hundred twenty-five yeasts, yeast-like fungi, and algae, comprising 28 species and in...

متن کامل

Comparative Evaluation of the BD Phoenix Yeast ID Panel and Remel RapID Yeast Plus System for Yeast Identification

Becton Dickinson Phoenix Yeast ID Panel was compared to the Remel RapID Yeast Plus System using 150 recent clinical yeast isolates and the API 20C AUX system to resolve discrepant results. The concordance rate between the Yeast ID Panel and the RapID Yeast Plus System (without arbitration) was 93.3% with 97.3% (146/150) and 95.3% (143/150) of the isolates correctly identified by the Becton Dick...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 36 4  شماره 

صفحات  -

تاریخ انتشار 1998