Neurointerventional guide sheath.

نویسندگان

  • U S Kanamalla
  • J P Kochan
چکیده

We read with interest Luzardo et al’s technical note in the December issue of the AJNR. Although we are pleased that the new Envoy 6F guide catheter (Cordis, Miami Lakes, Fla) facilitated a dualmicrocatheter procedure with a single arterial access, it should be noted that this is by no means a new technique. The 6F Envoy guide catheter with an inner diameter of 0.070 inches and outer diameter of 2.0 mm is comparatively new, but we have been using the same approach to perform balloon-assisted coiling with a 5F Shuttle guide sheath (Shuttle-SL; Cook, Bloomington, Ind) for more than 4 years. The 5F Shuttle guide sheath is currently our preferred guide sheath for endovascular management of intracranial aneurysms. The 5F Shuttle guide sheath has an inner diameter of 0.074 inches and an outer diameter of 0.090 inches (2.3 mm). For the purpose of balloon-assisted coil embolization, one could easily pass a compliant balloon catheter such as the HyperForm or HyperGlide (Micro Therapeutics, Irvine, Calif) and a standard 0.010or 0.014-inch microcatheter through the Shuttle. We have used this method for other dual-catheter techniques (eg, temporary proximal balloon occlusion with nondetachable balloon catheters and coaxial coil and foreign body retrieval with the Goose Neck Snare [Microvena, Vadnais Heights, Minn] or the Retriever device [Target Therapeutics/Boston Scientific, Fremont, Calif]). The Shuttle guide sheath is a hydrophilic-coated braided sheath that provides excellent stability during the procedures. It has a soft, radiopaque tip and is kink resistant. Cook’s Shuttle sheaths have 2 inner dilators with the 5F system (0.018 or 0.038 inch), which allows for a better transition between the wire, inner dilator, and sheath. It also comes with a side port, which facilitates contrast injection. In addition, a Tuohy rotating hemostatic valve can be connected to the side port, through which one could pass the Micro Therapeutics balloon catheter facilitating individual control of each microcatheter. Because our patients typically receive anticoagulants, on completion of the procedure we exchange the 5F Shuttle guide sheath for a standard 5F femoral arterial access sheath, which remains sutured in place overnight. We would also like to point out that, at the end of the procedure, the hole in the femoral artery is 5F when a Shuttle is used as opposed to 6F when the Envoy guiding catheter is used. As mentioned in the article, we agree that the use of this technique has resulted in reduced periprocedural risk when compared with separate femoral arterial catheterizations. We have experienced no technical complications with the use of the 5F Shuttle in conjunction with 2 microcatheters.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Minimally invasive cone beam CT-guided evacuation of parenchymal and ventricular hemorrhage using the Apollo system: proof of concept in a cadaver model

INTRODUCTION The Apollo system (Penumbra Inc, Alameda, California, USA) is a low profile irrigation-aspiration system designed for the evacuation of intracranial hemorrhage. OBJECTIVE To demonstrate the feasibility of using Apollo in combination with cone beam CT guidance. METHODS Parenchymal (n=1) and mixed parenchymal-intraventricular hematomas (n=1) were created in cadaver heads using a ...

متن کامل

Prospective comparison of angio-seal versus manual compression for hemostasis after neurointerventional procedures under systemic heparinization.

BACKGROUND AND PURPOSE The use of arterial closure device in patients with prolonged high ACT values has not been extensively studied. The aim of this study was to compare the safety and efficacy of an arterial closure device, Angio-Seal, with manual compression in patients on anticoagulation following neurointerventional procedures. MATERIALS AND METHODS This was a 2-center prospective study...

متن کامل

Transbronchial needle aspiration through a guide sheath with endobronchial ultrasonography (GS-TBNA) for peripheral pulmonary lesions.

PURPOSE Although, endobronchial ultrasonography with a guide sheath is becoming a common procedure for the diagnosis of peripheral pulmonary lesions, there remain to be some inaccuracies in cases wherein the probe is located outside the lesion. We tested whether adding transbronchial needle aspiration through a guide sheath to the conventional technique increases efficacy for diagnosing periphe...

متن کامل

Feasibility of the Transradial or the Transbrachial Approach in Various Neurointerventional Procedures

PURPOSE The generally preferred vascular access for neurointerventional procedures is the transfemoral approach (TFA). In complicated cases such as patients with aortic diseases or tortuous vessels, transradial or transbrachial approaches (TRA or TBA) could be good alternatives. The purpose of this study is to review a single medical center experience using the alternative accesses. MATERIALS...

متن کامل

Newly Designed Sheaths for Gastroduodenal Intervention: An Experimental Study in a Phantom and Dogs

OBJECTIVE To evaluate the usefulness of newly designed sheaths for gastroduodenal intervention in a gastric phantom and dogs. MATERIALS AND METHODS A regular sheath was made using a polytetrafluoroethylene tube (4 mm in diameter, 90 cm long) with a bent tip (4 cm long, 100 degree angle). For the supported type of sheath, a 5 Fr catheter was attached to a regular sheath to act as a side lumen....

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 27 5  شماره 

صفحات  -

تاریخ انتشار 2006