Real-time intraocular pressure measurement during phacoemulsification in dogs ex vivo
نویسندگان
چکیده
This study was performed to evaluate changes in intraocular pressure (IOP) during standard coaxial phacoemulsification using 4 different bottle heights (BHs) and 2 different incision sizes. Coaxial phacoemulsification was performed with a venturi-based machine in 8 enucleated canine eyes through 3.0 and 3.2 mm clear corneal incisions (CCIs). A pressure transducer inserted in the peripheral cornea monitored the IOP in real-time. The surgery was subdivided into 4 stages: sculpt-segment removal, irrigation/aspiration, capsular polishing and viscoelastic removal. The mean IOP and the difference between the maximum and minimum IOPs were calculated at each stage and compared. The ultrasound time and volume of irrigation fluid used were recorded. The mean IOP increased with an elevation in the BH. The mean IOP in the irrigation/aspiration stage was significantly higher than that in the sculpt-segment removal stage at the same BH. The difference between the maximum and minimum IOP at each stage was greater in the 3.2 mm than the 3.0 mm CCIs, although the mean IOP was lower with the 3.2 mm than the 3.0 mm CCIs. The ultrasound time and irrigation fluid volume were greater with the 3.2 mm than the 3.0 mm CCIs. Therefore, fluidic parameters during each stage could be reassessed and adjusted to reduce complications arising from an elevated IOP. Phacoemulsification with 3.0 mm CCIs at a lower BH might lead to less stress on the eye from IOP fluctuations, ultrasound energy and irrigation fluid.
منابع مشابه
Intraocular pressure and calculated diastolic ocular perfusion pressure during three simulated steps of phacoemulsification in vivo.
PURPOSE To investigate the fluctuations of directly measured intraocular pressure (IOP) and induced diastolic ocular perfusion pressure (DOPP) during three simulated steps of phacoemulsification in vivo. METHODS Twenty-five eyes of 25 patients who underwent phacoemulsification were evaluated. A pressure transducer was inserted into the anterior chamber to measure IOP directly. The cortical cl...
متن کاملPhacoemulsification and acryl foldable intraocular lens implantation in dogs: 32 cases
This study evaluated the surgical outcome and complications of phacoemulsification and the implantation of an acryl foldable intraocular lens (IOL) with a squared edge in dogs with cataracts. Thirty-two eyes from 26 dogs were examined. The mean follow up period was 75.9 days ranging from 23 to 226 days. The complications after phacoemulsification were posterior capsular opacity (PCO) around the...
متن کاملEvaluation of the Ex-PRESS(®) P-50 implant under scleral flap in combined cataract and glaucoma surgery.
AIM To evaluate the efficacy and safety of glaucoma drainage device Ex-PRESS(®) P-50 for combined cataract surgery and glaucoma. METHODS Patients having cataract and open angle glaucoma or patients with open advanced glaucoma which needed two or more antiglaucoma medications were included. Combined cataract surgery and glaucoma with Ex-PRESS(®) P-50 model placed under scleral flap was perform...
متن کاملIntraocular pressure during phacoemulsification.
PURPOSE To assess changes in intraocular pressure (IOP) during standard coaxial or bimanual microincision phacoemulsification. SETTING Oregon Eye Center, Eugene, Oregon, USA. METHODS Bimanual microincision phacoemulsification (microphaco) was performed in 3 cadaver eyes, and standard coaxial phacoemulsification was performed in 1 cadaver eye. A pressure transducer placed in the vitreous cav...
متن کاملEvaluation of Ex-PRESS implantation combined with phacoemulsification in primary angle-closure glaucoma
To evaluate the safety and efficacy of Ex-PRESS (R50) implantation combined with phacoemulsification in primary angle-closure glaucoma (PACG) patients with cataract.Twenty-four eyes of 24 patients with unregulated PACG underwent combined cataract and glaucoma surgery. After phacoemulsification and intraocular lens implantation, the Ex-PRESS (R-50) was inserted into the anterior chamber under a ...