Contribution of lymphatic absorption to loss of ultrafiltration and solute clearances in continuous ambulatory peritoneal dialysis.
نویسندگان
چکیده
The contribution of peritoneal cavity lymphatic absorption to ultrafiltration kinetics and solute clearances in continuous ambulatory peritoneal dialysis was evaluated in patients with normal (group 1) and high (group 2) peritoneal permeability X area during 4-h exchanges using 2 liters 2.5% dextrose dialysis solution with 30 g added albumin. Cumulative lymphatic drainage in all continuous ambulatory peritoneal dialysis (CAPD) patients averaged 358 +/- 47 ml per 4-h exchange and reduced cumulative net transcapillary ultrafiltration at the end of the exchange by 58 +/- 7.2%. The peak ultrafiltration volume was observed before osmotic equilibrium between serum and dialysate was reached and occurred when the net transcapillary ultrafiltration rate had decreased to equal the lymphatic absorption rate. Thereafter the lymphatic absorption rate exceeded the net transcapillary ultrafiltration rate, and intraperitoneal volume decreased. Extrapolated to 4 X 2 liters, 2.5% dextrose, 6-h exchanges per d, lymphatic drainage reduced potential daily net ultrafiltration by 83.2 +/- 10.2%, daily urea clearance by 16.9 +/- 1.9%, and daily creatinine clearance by 16.5 +/- 1.9%. Although lymphatic absorption did not differ between the two groups, lymphatic drainage caused a proportionately greater reduction in net ultrafiltration in group 2 (P less than 0.025), because these patients had more rapid dialysate glucose absorption (P less than 0.05) and less cumulative transcapillary ultrafiltration (P less than 0.01). These findings indicate that cumulative lymphatic drainage significantly reduces net ultrafiltration and solute clearances in CAPD and that ultrafiltration failure in CAPD occurs when daily lymphatic absorption equals or exceeds daily transcapillary ultrafiltration. Reduction of lymphatic absorption may provide a means for future improvement in the efficiency of CAPD.
منابع مشابه
Correlation between Ultrafiltration Coefficient and Effective Lymphatic Absorption Rate in Continuous Ambulatory Peritoneal Dialysis Patients: A Possible Paradigm Shift
Background: The relative contribution of transcapillary water movement and lymphatic reabsorption in peritoneal dialysis (PD) is a critical issue, particularly in patients with ultrafiltration failure (UFF). Based on routine results obtained from the PD Adequest 2.0 software, the present study aimed to re-evaluate the separate effects of transcapillary water movement and lymphatic reabsorption ...
متن کاملDay-to-day variability of fluid and solute transport in upright and recumbent positions during CAPD.
BACKGROUND The effect of posture on peritoneal transport characteristics during CAPD is unpredictable because (1) although the capillary pressure is higher in the upright position, the intraperitoneal pressure is also elevated, and (2) the contact of dialysate with the subdiaphragmatic lymphatics is probably more extensive during recumbency. METHODS In eight CAPD patients, six peritoneal perm...
متن کاملPeritoneal fluid and solute transport: influence of treatment time, peritoneal dialysis modality, and peritonitis incidence.
The integrity of the peritoneal membrane in peritoneal dialysis (PD) is of major importance for adequate dialysis and fluid balance. However, alterations in peritoneal fluid transport, such as ultrafiltration failure, often develop during long-term PD. To investigate peritoneal solute and fluid transport and to analyze the influence of treatment time, peritonitis incidence, and PD modality (con...
متن کاملLongitudinal hemodiafilter performance in modeled continuous renal replacement therapy.
BACKGROUND/AIMS With advanced anticoagulation, many institutions operate continuous renal replacement therapy (CRRT) circuits longer than manufacturers' recommendations. This extended use may change hemodiafilter performance and clearance properties. However, hemodiafilter performance over time has not been assessed. We investigated solute clearance over time in modeled CRRT. METHODS In vitro...
متن کاملDeterminants of sodium removal with tidal automated peritoneal dialysis.
In a comprehensive evaluation of dialysis adequacy, major attention has been recently paid to fluid and Na balance. Removal of Na has been reported to be significantly poorer with automated peritoneal dialysis (APD) than with continuous ambulatory peritoneal dialysis. Only limited data on Na removal with tidal APD have been published. We analyzed peritoneal Na mass balance in 122 separate night...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of clinical investigation
دوره 80 5 شماره
صفحات -
تاریخ انتشار 1987