Cost-effective utilization of single photon emission computed tomography (SPECT) in decision making for epilepsy surgery
نویسندگان
چکیده
PURPOSE To investigate the utility of single photon emission computed tomography (SPECT) without subtraction and MRI co-registration in decision making for epilepsy surgery. METHODS Patients with refractory epilepsy and nonlocalizing or discordant non-invasive data (clinical, long-term VEEG, and MRI) were subjected to interictal and ictal SPECT studies before planning invasive or surgical strategy. Final localization was based upon the preoperative information and seizure freedom after surgery. SPECT was considered to be useful for decision-making if it obviated the need for intracranial monitoring or influenced its planning. RESULTS 61 patients (mean age, 25.1±8.3 years) underwent SPECT studies between January 2004 and December 2008. Twenty-two patients had mesial temporal lobe epilepsy (MTLE), 13 had neocortical temporal lobe epilepsy (NTLE), and 26 had extratemporal lobe epilepsy (ETLE). As compared to ETLE, SPECT provided more localizing information (77.3% vs 46.2%, p=0.006) and influenced the final decision-making (45.4% vs 11.53%, p=0.005) in a significantly higher number of patients with MTLE. SPECT was particularly useful in patients with lesional TLE and nonlocalizing ictal data and in those with dual pathologies. SPECT did not provide any additional information in patients having either TLE or ETLE with normal MRI. CONCLUSIONS SPECT is useful in a selected group of patients and unlikely to provide additional information in others. By restricting its use in patients who are likely to be benefited, a cost-effective utilization strategy can be employed in countries with limited resources. Due to the small number, these findings need to be validated in a larger group of patients.
منابع مشابه
Utilization of an optimum low-pass filter during filtered back-projection in the reconstruction of single photon emission computed tomography images of small structures
Introduction:Low-pass filters eliminate noise, and accordingly improve the quality of filtered back-projection (FBP) in the reconstruction of single photon emission computed tomography (SPECT) images. This study aimed at selection of an optimum low-pass filter for FBP reconstruction of SPECT images of small structures. Material and Methods:Sp...
متن کامل[The utility of interictal SPECT in temporal lobe epilepsy].
INTRODUCTION Interictal brain single photon emission computed tomography (SPECT) is used in the presurgical evaluation of patients with complex partial epilepsy. The aim of the present study was to compare interictal SPECT, MRI and video-electroencephalography (EEG) for seizure focus localization in patients with temporal lobe epilepsy, one year after temporal lobectomy, in order to determine t...
متن کاملBrain Single Photon Emission Computed Tomography Scan (SPECT) and Functional MRI in Systemic Lupus Erythematosus Patients with Cognitive Dysfunction: A Systematic Review
Objective(s): Systemic lupus erythematosus (SLE) is an autoimmune disease with a wide range of clinical manifestations. Cognitive dysfunction is one of the manifestations that could present prior to the emergence of any other neuropsychiatric involvements in SLE. Cognitive dysfunction is a subtle condition occurring with ahigh frequency. However, there is no data on the correlation of cognitive...
متن کاملMonte Carlo Study of the Effect of Backscatter Materail Thickness on 99mTc Source Response in Single Photon Emission Computed Tomography
Introduction SPECT projections are contaminated by scatter radiation, resulting in reduced image contrast and quantitative errors. Backscatter constitutes a major part of the scatter contamination in lower energy windows. The current study is an evaluation of the effect of backscatter material on FWHM and image quality investigated by Monte Carlo simulation. Materials and Methods SIMIND program...
متن کاملImage Optimization in Single Photon Emission Computed Tomography by Hardware Modifications with Monte Carlo Simulation
Introduction: In Single Photon Emission Computed Tomography (SPECT), the projection data used for image reconstruction are distorted by several factors, including attenuation and scattering of gamma rays, collimator structure, data acquisition method, organ motion, and washout of radiopharmaceuticals. All these make reconstruction of a quantitative SPECT image very difficult. Simulation of a SP...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Seizure
دوره 20 شماره
صفحات -
تاریخ انتشار 2011