Reconstruction Algorithms Influence the Follow-Up Variability in the Longitudinal CT Emphysema Index Measurements

نویسندگان

  • Bruno Hochhegger
  • Klaus Loureiro Irion
  • Edson Marchiori
  • Jose Silva Moreira
چکیده

OBJECTIVE We wanted to compare the variability in the longitudinal emphysema index (EI) measurements that were computed with standard and high resolution (HR) reconstruction algorithms (RAs). MATERIALS AND METHODS We performed a retrospective review of 475 patients who underwent CT for surveillance of lung nodules. From this cohort, 50 patients (28 male) were included in the study. For these patients, the baseline and follow-up scans were acquired on the same multidetector CT scanner and using the same acquisition protocol. The CT scans were reconstructed with HR and standard RAs. We determined the difference in the EI between CT1 and CT2 for the HR and standard RAs, and we compared the variance of these differences. RESULTS The mean of the variation of the total lung volume was 0.14 L (standard deviation [SD] = 0.13 L) for the standard RA and 0.16 L (SD = 0.15 L) for the HR RA. These differences were not significant. For the standard RA, the mean variation was 0.13% (SD = 0.44%) for EI -970 and 0.4% (SD = 0.88%) for EI -950; for the HR RA, the mean variation was 1.9% (SD = 2.2%) for EI -970 and 3.6% (SD = 3.7%) for EI -950. These differences were significant. CONCLUSION Using an HR RA appears to increase the variability of the CT measurements of the EI.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The influence of using different reconstruction algorithms on sensitivity of quantitative 18F-FDG-PET volumetric measures to background activity variation

Introduction: This study aims to investigate the influence of background activity variation on image quantification in differently reconstructed PET/CT images. Methods: Measurements were performed on a Discovery-690 PET/CT scanner using a custom-built NEMA-like phantom. A background activity level of 5.3 and 2.6 kBq/ml 18F-FDG were applied. Ima...

متن کامل

Normal variance in emphysema index measurements in 64 multidetector‐row computed tomography

The purpose of this study was to identify the normal variance of emphysema index (EI) measured in examinations acquired with 64 multidetector-row computed tomography (64-MDCT). A longitudinal, noninterventional study was performed retrieving all patients in our institution who are currently registered in our lung nodule protocol. All patients with clinical, functional, or significant radiologic...

متن کامل

Computed Tomography Measurement of Rib Cage Morphometry in Emphysema

BACKGROUND Factors determining the shape of the human rib cage are not completely understood. We aimed to quantify the contribution of anthropometric and COPD-related changes to rib cage variability in adult cigarette smokers. METHODS Rib cage diameters and areas (calculated from the inner surface of the rib cage) in 816 smokers with or without COPD, were evaluated at three anatomical levels ...

متن کامل

Bayesian Sample Size Determination for Joint Modeling of Longitudinal Measurements and Survival Data

A longitudinal study refers to collection of a response variable and possibly some explanatory variables at multiple follow-up times. In many clinical studies with longitudinal measurements, the response variable, for each patient is collected as long as an event of interest, which considered as clinical end point, occurs. Joint modeling of continuous longitudinal measurements and survival time...

متن کامل

Normalized emphysema scores on low dose CT: Validation as an imaging biomarker for mortality

The purpose of this study is to develop a computed tomography (CT) biomarker of emphysema that is robust across reconstruction settings, and evaluate its ability to predict mortality in patients at high risk for lung cancer. Data included baseline CT scans acquired between August 2002 and April 2004 from 1737 deceased subjects and 5740 surviving controls taken from the National Lung Screening T...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2011