Neutron Detection Time Distributions of Multisphere LiI Detectors And AB Remmeter at A 20-MeV Electron Linac
نویسندگان
چکیده
Neutron detection time distribution is an important factor for the dead-time correction for moderator type neutron detectors used in pulsed radiation fields. Measurements of the neutron detection time distributions of multisphere LiI detectors (2Ó, 3Ó, 5Ó, 8Ó, 10Ó and 12Ó in diameter) and AB remmeter were made inside a ANL 20-MeV electron Linac room. Calculations of the neutron detection time distributions were also made using Monte Carlo codes. The first step was to calculate the neutron energy spectra at the target and detector positions, using a coupled EGS4-MORSE code with a giant-resonant photoneutron generation scheme. The calculated detector spectrum was found in agreement with the multisphere measurements. Then, neutrons hitting the detector surface were scored as function of energy and the travel time in the room using MCNP. Finally, the above neutron fluence as function of energy and travel time was used as the source term, and the neutrons detected by 6 Li or 10 B in the sensor were scored as a function of detection time for each detector using MCNP. The calculations of the detection time distributions agree with the measurements. The results also show that the detection time distributions of detectors with large moderators depend mainly on the moderator thickness and neutron spectrum. However, for small detectors, the neutron travel time in the field is also crucial. Therefore, all four factors (neutron spectrum, neutron travel time in the field, detector moderator thickness and detector response function) may play interrelated roles in the detection time distributions of moderator type detectors.
منابع مشابه
Dental Materials Effect in Neutron Contamination: Electron Mode of a Linac
Background: Neutron contamination is produced in electron beams of linac when tooth or dental materials are located in the path of beam. Objective: This study aims to determine the neutron dose contamination from different dental restoration materials in electron mode of a linac. Material and Methods: In this experimental study, the neutron dose contamination was calculated in the p...
متن کاملRecent Developments in Nuclear Data Measurement capabilities at the Gaerttner LINAC Center at RPI
The Gaerttner LINAC Center at RPI uses a 60 MeV electron linear accelerator to produce short pulses of neutrons with duration of 5-5000 ns. The main research thrust at the Center is nuclear data for nuclear reactors and criticality safety applications. The Center includes several setups for time-of-flight measurements including neutron transmission, capture and scattering detectors, and a lead ...
متن کاملDesign and Simulation of Photoneutron Source by MCNPX Monte Carlo Code for Boron Neutron Capture Therapy
Introduction Electron linear accelerator (LINAC) can be used for neutron production in Boron Neutron Capture Therapy (BNCT). BNCT is an external radiotherapeutic method for the treatment of some cancers. In this study, Varian 2300 C/D LINAC was simulated as an electron accelerator-based photoneutron source to provide a suitable neutron flux for BNCT. Materials and Methods Photoneutron sources w...
متن کاملExperimental and Monte Carlo studies on the response of CR-39 detectors to Am-Be neutron spectrum
Background: The Poly-Allyl Diglycol Carbonate (PADC) detector is of particular interest for development of a fast neutron dosimeter. Fast neutrons interact with the constituents of the CR-39 detector and produce H, C and O recoils, as well as (n, α) reaction. These neutron- induced charged particles contribute towards the response of CR-39 detectors. Material and Methods: Electrochemical...
متن کاملNeutron Spectra and Dosimetric Quantities Outside Typical Concrete Shielding of Synchrotron Facilities
Neutron energy spectra at high energy electron accelerators outside concrete shielding of various thicknesses (30 to 240 cm at 65-95 degrees) have been calculated at three electron energies (100 MeV, 1 and 10 GeV) and an optimum Cu target of 30.48 cm long and 5.08 cm in radius with the FLUKA Monte Carlo code. Dose quantities such as the protection quantity of Effective dose E and the operationa...
متن کامل