The effects of low tidal ventilation on lung strain correlate with respiratory system compliance

نویسندگان

  • Jianfeng Xie
  • Fang Jin
  • Chun Pan
  • Songqiao Liu
  • Ling Liu
  • Jingyuan Xu
  • Yi Yang
  • Haibo Qiu
چکیده

BACKGROUND The effect of alterations in tidal volume on mortality of acute respiratory distress syndrome (ARDS) is determined by respiratory system compliance. We aimed to investigate the effects of different tidal volumes on lung strain in ARDS patients who had various levels of respiratory system compliance. METHODS Nineteen patients were divided into high (Chigh group) and low (Clow group) respiratory system compliance groups based on their respiratory system compliance values. We defined compliance ≥0.6 ml/(cmH2O/kg) as Chigh and compliance <0.6 ml/(cmH2O/kg) as Clow. End-expiratory lung volumes (EELV) at various tidal volumes were measured by nitrogen wash-in/washout. Lung strain was calculated as the ratio between tidal volume and EELV. The primary outcome was that lung strain is a function of tidal volume in patients with various levels of respiratory system compliance. RESULTS The mean baseline EELV, strain and respiratory system compliance values were 1873 ml, 0.31 and 0.65 ml/(cmH2O/kg), respectively; differences in all of these parameters were statistically significant between the two groups. For all participants, a positive correlation was found between the respiratory system compliance and EELV (R = 0.488, p = 0.034). Driving pressure and strain increased together as the tidal volume increased from 6 ml/kg predicted body weight (PBW) to 12 ml/kg PBW. Compared to the Chigh ARDS patients, the driving pressure was significantly higher in the Clow patients at each tidal volume. Similar effects of lung strain were found for tidal volumes of 6 and 8 ml/kg PBW. The "lung injury" limits for driving pressure and lung strain were much easier to exceed with increases in the tidal volume in Clow patients. CONCLUSIONS Respiratory system compliance affected the relationships between tidal volume and driving pressure and lung strain in ARDS patients. These results showed that increasing tidal volume induced lung injury more easily in patients with low respiratory system compliance. TRIAL REGISTRATION Clinicaltrials.gov identifier NCT01864668 , Registered 21 May 2013.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The effects of low tidal ventilation on lung strain correlate with pulmonary compliance

Methods Nineteen patients were divided into high (Chigh group) and low pulmonary compliance (Clow group) groups based on their pulmonary compliance values (0.6 ml/[cmH2O·kg]). End-expiratory lung volumes (EELV) with different tidal volumes (VT at baseline and at 6, 8, 10 and 12 ml/kg predicted body weight [PBW]) were measured by nitrogen wash-in/washout. Lung strain was calculated as the ratio ...

متن کامل

Pressure-control ventilation in managing acute respiratory distress syndrome

adjusts inspiratory gas flow to maintain Paw as a square wave. Titrating inspiratory flow rate (V̇I) to maintain Paw as a square wave results in a variable, decreasing ramp flow waveform (Figure 1A). Peak V̇ occurs as inspiration commences, so that the flow-resistive properties of the patientventilator system can be utilised to create a ‘pressure-step’ that approaches the peak Paw target (Paw = ̇ ...

متن کامل

Comparing the Effect of Adaptive Support Ventilation (ASV) and Synchronized Intermittent Mandatory Ventilation (SIMV) on Respiratory Parameters in Neurosurgical ICU Patients

BACKGROUND Various modes of mechanical ventilation have different effects on respiratory variables. Lack of patients' neuro-ventilatory coordination and increasing the work of breathing are major disadvantages in mechanically ventilated patients. OBJECTIVES This study is conducted to compare the respiratory parameters differences in Adaptive support ventilation (ASV) and synchronized intermit...

متن کامل

Physiological effects of oxidized exogenous surfactant in vivo: effects of high tidal volume and surfactant protein A.

Oxidative damage to surfactant can decrease lung function in vivo. In the current study, our two objectives were: 1) to examine whether the adverse effects of oxidized surfactant would be accentuated in animals exposed to high tidal volume ventilation, and 2) to test whether supplementation with surfactant protein A (SP-A) could improve the function of oxidized surfactant in vivo. The first obj...

متن کامل

Impacts of different ventilation modes on respiratory mechanics, blood gas and hemodynamics in elderly patients with laparoscopic cholecystectomy

In this study, the impacts of different ventilation modes on respiratory mechanics, blood gas and hemodynamics in elderly patients undergoing laparoscopic cholecystectomy (LC) were compared. 60 LC patients were divided into 3 groups: group L (low tidal volume), group L + P (low tidal volume + positive end expiratory pressure) and group C (large tidal volume). Endotracheal intubation was placed ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 21  شماره 

صفحات  -

تاریخ انتشار 2017