Prospective monitoring study: isolating Legionella pneumophila in a hospital water system located in the obstetrics and gynecology ward after eradication of Legionella anisa and reconstruction of shower units.

نویسندگان

  • Michio Koide
  • Tomoko Owan
  • Chikara Nakasone
  • Natsuo Yamamoto
  • Shusaku Haranaga
  • Futoshi Higa
  • Masao Tateyama
  • Nobuhisa Yamane
  • Jiro Fujita
چکیده

We previously reported on the sporadic contamination by Legionella anisa of shower units and sink taps at Ryukyu University Hospital. Starting in July 2003, the neonatal area underwent an 8-month reconstruction, and in March 2005, the boiler system was replaced. We therefore examined shower water and tap water for the presence of Legionella just after replacement of the boiler system. In 3 of the 8 water samples collected from the remodeled area, we isolated Legionella pneumophila serogroup 1 and L. anisa. Moreover, L. pneumophila serogroup 1 was isolated in 4 of the 5 water samples gathered from the unreconstructed area of the same floor. Random amplified polymorphic DNA analysis suggested that a single clone of L. pneumophila might exist throughout the floors of the water distribution system. We replaced the shower units at the Legionella-positive site, and began flushing the sink-faucets with water heated to 55N for at least 1 h every morning. As a result, Legionella was not subsequently isolated in water samples. In this prospective study, we identified a central contamination by L. pneumophila serogroup 1 and showed that flushing with hot tap water was effective to counter this situation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Investigation of Legionella Pneumophila bacteria in hospital water supply systems

Introduction: Legionella Pneumophila bacteria is known as one of the most important nosocomial infections and the most common cause of death in patients. This study was aimed to identify Legionella Pneumophila bacteria in hospital water supply systems. Material and Methods: This descriptive cross-sectional study was performed to identify Legionella pneumophila in hot and cold-water systems of i...

متن کامل

Isolation of Legionella pneumophila from Tehran Hospital Water Samples

Over a Period of three months (summer), 108 samples of water collected from four hospitals in Te-hran. They were taken from numerous potable and non-potable water, including main supply cis-terns, calorifiers, hot and cold tap water, shower, cooling tower and drain of air condition system. Culturing of concentrated and non-concentrated water samples on Buffered Charcoal Yeast Extract (BCYE) Aga...

متن کامل

Legionella anisa and hospital water systems.

V.L. Yu (*) · J.E. Stout VA Medical Center, Infections Disease Section, 111 E-U, University Drive C, Pittsburgh, PA 15240, USA Tel. 1-412-688-6643; Fax 1-412-688-6950 e-mail: [email protected] To the Editor, Concerning the article by Yamamoto et al. entitled “Isolation of Legionella anisa from multiple sites of a hospital water distribution system”; published recently in the Journal of Infection and...

متن کامل

Legionella anisa, a possible indicator of water contamination by Legionella pneumophila.

Legionella anisa is one of the most frequent species of Legionella other than Legionella pneumophila in the environment and may be hospital acquired in rare cases. We found that L. anisa may mask water contamination by L. pneumophila, suggesting that there is a risk of L. pneumophila infection in immunocompromised patients if water is found to be contaminated with Legionella species other than ...

متن کامل

Role of environmental surveillance in determining the risk of hospital-acquired legionellosis: a national surveillance study with clinical correlations.

OBJECTIVE Hospital-acquired Legionella pneumonia has a fatality rate of 28%, and the source is the water distribution system. Two prevention strategies have been advocated. One approach to prevention is clinical surveillance for disease without routine environmental monitoring. Another approach recommends environmental monitoring even in the absence of known cases of Legionella pneumonia. We de...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Japanese journal of infectious diseases

دوره 60 1  شماره 

صفحات  -

تاریخ انتشار 2007