Continuous Electron Beam Accelerator Facility,
نویسنده
چکیده
We use local quark-hadron duality to estimate the purely nonperturbative soft contribution to the γ * p → ∆ form factors. Our results are in agreement with existing experimental data. We predict that the ratio G * E (Q 2)/G * M (Q 2) is small for all accessible Q 2 , in contrast to the pQCD expectations that G * E (Q 2) → −G * M (Q 2).
منابع مشابه
Fast Feedback System for Energy and Beam Stabilization
The electron beams being delivered to targets of the Continuous Electron Beam Accelerator Facility (CEBAF) at Thomas Jefferson National Accelerator Facility (Jefferson Lab) are plagued with undesirable positional and energy fluctuations. These fluctuations primarily occur at harmonics of the power line frequency (60, 120, 180, etc. hertz), and their cause is rooted in electromagnetic fields gen...
متن کاملReview of Alignment Activities at Jefferson Lab
The Thomas Jefferson National Accelerator Facility (Jefferson Lab) comprises a 6 GeV continuous electron beam accelerator (CEBAF) delivering beam to three experimental halls, and a kilowatt range tunable free electron laser (FEL), currently being upgraded to a 10 kW machine. The progression into steady state experimental runs at the facility has allowed the alignment group the opportunity to in...
متن کاملTHE CONTINUOUS ELECTRON BEAM ACCELERATOR FACILITY: CEBAF at the Jefferson Laboratory
■ Abstract The Jefferson Laboratory’s superconducting radiofrequency (srf ) Continuous Electron Beam Accelerator Facility (CEBAF) provides multi-GeV continuouswave (cw) beams for experiments at the nuclear and particle physics interface. CEBAF comprises two antiparallel linacs linked by nine recirculation beam lines for up to five passes. By the early 1990s, accelerator installation was proceed...
متن کاملA Parasitic Electron Be 2 W and Tagged Photon Beam
A parasitic electron beam facility has been developed at the Mark III linear accelerator, Stanford University. The beam has been used both for physics experiments and for counter and spark chamber tests, even though the beam intensity is very low. A tagged photon beam was installed as part of the facility. A description of the two beams and a short discussion of the applications of these beams ...
متن کاملThe Slac Pulsed X-ray Facility*
The Stanford Linear Accelerator Center (SLAC) operates a high energy (up to 33 GeV) linear accelerator delivering pulses up to a few microseconds wide. The pulsed nature of the electron beam creates problems in the detection and measurement of radiation both from the accelerator beam and the klystrons that provide the RF power for the accelerator. Hence, a pulsed x-ray facility has been built a...
متن کاملMeasured radiation and background levels during transmission of megawatt electron beams through millimeter apertures
We report measurements of photon and neutron radiation levels observed while transmitting a 0.43 MW electron beam through millimeter-sized apertures and during beam-off, but accelerating gradient RF-on, operation. These measurements were conducted at the Free-Electron Laser (FEL) facility of the Jefferson National Accelerator Laboratory (JLab) using a 100 MeV electron beam from an energy-recove...
متن کامل