Unusual complication after aortic valve replacement.
نویسندگان
چکیده
We present a report of a postoperative left ventricular-right atrial (LV-RA) communication after aortic valve replacement. Such intracardiac defects are rare but encountered occasionally after valve surgery. The diagnosis was made by use of transesophageal echocardiography with echo-Doppler and color-flow imaging. Complications of LV-RA shunts and differential diagnosis are discussed.
منابع مشابه
Bicuspid Aortic Valve: An Unusual Cause of Aneurysm of Left Coronary Sinus of Valsalva
Bicuspid aortic valve is traditionally considered an innocuous congenital anomaly. Due to a better and widespread availability of non-invasive imaging techniques, it has come to the fore that 30% of these cases develop complications, viz., valve abnormality (aortic regurgitation and stenosis), and aneurysm of aortic root and ascending aorta. Sinus of Valsalva aneurysm is an uncommon complicatio...
متن کاملAn unusual lethal complication associated with Starr-Edwards prosthetic aortic valve holder.
This is the first report of an unusual fatal complication associated with the Starr-Edwards prosthetic aortic valve holder. The patient died 51 days after replacement of his aortic valve with a Starr-Edwards prosthetic aortic valve. The cause of death was coronary arterial embolus caused by a fragment broken off of the prosthetic aortic valve holder.
متن کاملSuccessful Use of Two Thrombolytic Drugs in Prosthetic Mitral and Aortic Valve Thrombosis
Introduction: Prosthetic valve thrombosis is a rare and severe complication of valve replacement, most often encountered with a mechanical prosthesis. The significant morbidity and mortality associated with this condition warrant rapid diagnostic evaluation. Although surgery is the first-line therapy in symptomatic obstructive mechanical valve thrombosis, thrombolytic therapy has been used as a...
متن کاملAn Unusual Complication After Rupture of the SAPIEN 3 Valve Balloon During Transcatheter Aortic Valve Replacement.
Manuscript received January 7, 2016; accepted January 14, 2016. tomography scan showed an aortic annulus measuring 482 cm with an area-derived diameter of 24.8 mm and prominent calcifications at the sinotubular junction (Figure 1). An Edwards SAPIEN 3 (S3) 26-mm valve (Edwards Lifesciences, Irvine, California) was accordingly implanted via a left femoral approach. However, at the end of the val...
متن کاملA Very Late Presentation of a Right Coronary Artery Occlusion After Transcatheter Aortic Valve Replacement
Involvement of the coronary ostia is a rare complication after transcatheter aortic valve replacement (TAVR). This complication has been more commonly described immediately after valve deployment. This is the first reported case of delayed coronary obstruction caused by TAVR 6 months after the procedure.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Interactive cardiovascular and thoracic surgery
دوره 7 1 شماره
صفحات -