Intravascular ultrasound assessment of neointima distribution and the length of stent that was free of intravascular ultrasound-detectable intimal hyperplasia in paclitaxel-eluting stents.
نویسندگان
چکیده
Using data from the ASian Paclitaxel-Eluting Stent Clinical Trial, a 3-center, randomized, placebo-controlled trial of nonpolymeric paclitaxel-coated stents with a single center, 81-patient intravascular ultrasound (IVUS) substudy, the length of a stent that was free of IVUS-detectable intimal hyperplasia measured 3.2 +/- 4.8 mm in placebo stents, 6.1 +/- 5.6 mm in low-dose stents, and 8.7 +/- 6.1 mm in high-dose stents (p = 0.0029). IVUS percent neointima volume obstruction correlated with the length of this IVUS neointima-free segment (r = 0.785, p <0.0001); angiographic late lumen loss and follow-up diameter stenosis also correlated with the IVUS neointima-free length of the stents (r = 0.670, p <0.0001 and r = 0.679, p <0.0001, respectively.
منابع مشابه
Intravascular ultrasonic comparative analysis of degree of intimal hyperplasia produced by four different stents in the coronary arteries.
Intravascular ultrasound studies were performed at angiographic follow-up on 121 native coronary lesions treated with 1 bare metal stent (n = 50), high-dose dexamethasone-eluting stents (n = 18), non-polymer-based paclitaxel-eluting stents (n = 18), or sirolimus-eluting stents (n = 35). Paclitaxel- and sirolimus-eluting stents reduced mean intimal hyperplasia thickness compared with bare metal ...
متن کاملComparison of zotarolimus-eluting stents with sirolimus-eluting and paclitaxel-eluting stents: intimal hyperplasia and vascular changes assessed by volumetric intravascular ultrasound analysis.
BACKGROUND As a substudy of the large, randomized ZEST (Comparison of the Efficacy and Safety of Zotarolimus-Eluting Stent with Sirolimus-Eluting and PacliTaxel-Eluting Stent for Coronary Lesions) trial comparing first- and second-generation drug-eluting stents, we evaluated intimal hyperplasia (IH) and vascular changes using volumetric intravascular ultrasound analysis. METHODS AND RESULTS C...
متن کاملComparison of quantitative angiographic parameters with the magnitude of neointimal hyperplasia measured by volumetric intravascular ultrasound in patients treated with bare metal and nonpolymeric paclitaxel-coated stents.
We used data from the ASian Paclitaxel-Eluting Stent Clinical Trial (a 3-center, randomized, placebo-controlled trial of nonpolymeric paclitaxel-coated stents with a single-center intravascular ultrasound substudy) to compare angiographic indexes of drug-eluting stent efficacy with the magnitude of intimal hyperplasia (IH) assessed by intravascular ultrasound. Overall, percent IH (IH volume div...
متن کاملRelation of intimal hyperplasia thickness to stent size in paclitaxel-coated stents.
To determine the relation of intimal hyperplasia thickness to stent size in nonpolymeric paclitaxel-coated stents, intravascular ultrasound was performed after stent implantation and at 6 months. Similar to bare metal stents, this study demonstrated that intimal hyperplasia thickness is independent of stent size. There was no deleterious effect of the increased concentration associated with usi...
متن کاملOptical coherence tomographic analysis of in-stent neoatherosclerosis after drug-eluting stent implantation.
BACKGROUND We report findings from optical coherence tomography (OCT) of in-stent neoatherosclerosis as a cause of drug-eluting stent (DES) failure. METHODS AND RESULTS Optical coherence tomography and grayscale and virtual histology intravascular ultrasound were performed in 50 patients (30 stable, 20 unstable angina) with 50 DES in-stent restenosis lesions and intimal hyperplasia >50% of st...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The American journal of cardiology
دوره 95 1 شماره
صفحات -
تاریخ انتشار 2005