Comparison of the Mechanical Characteristics of a Universal Small Biplane Plating Technique Without Compression Screw and Single Anatomic Plate With Compression Screw.

نویسندگان

  • Paul Dayton
  • Joe Ferguson
  • Daniel Hatch
  • Robert Santrock
  • Sean Scanlan
  • Bret Smith
چکیده

To better understand the mechanical characteristics of biplane locked plating in small bone fixation, the present study compared the stability under cyclic cantilever loading of a 2-plate locked biplane (BPP) construct without interfragmentary compression with that of a single-plate locked construct with an additional interfragmentary screw (SPS) using surrogate bone models simulating Lapidus arthrodesis. In static ultimate plantar bending, the BPP construct failed at significantly greater load than did the SPS construct (556.2 ± 37.1 N versus 241.6 ± 6.3 N, p = .007). For cyclic failure testing in plantar bending at a 180-N starting load, the BPP construct failed at a significantly greater number of cycles (158,322 ± 50,609 versus 13,718 ± 10,471 cycles) and failure load (242.5 ± 25.0 N versus 180.0 ± 0.0 N) than the SPS construct (p = .002). For cyclic failure testing in plantar bending at a 120-N starting load, the results were not significantly different between the BPP and SPS constructs for the number of cycles (207,646 ± 45,253 versus 159,334 ± 69,430) or failure load (205.0 ± 22.4 N versus 185.0 ± 33.5 N; p = .300). For cyclic testing with 90° offset loading (i.e., medial to lateral bending) at a 120-N starting load, all 5 BPP constructs (tension side) and 2 of the 5 SPS constructs reached 250,000 cycles without failure. Overall, the present study found the BPP construct to have superior or equivalent stability in multiplanar orientations of force application in both static and fatigue testing. Thus, the concept of biplane locked plating, using 2 low profile plates and unicortical screw insertion, shows promise in small bone fixation, because it provides consistent stability in multiplanar orientations, making it universally adaptable to many clinical situations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Pitfall in Fixation of Distal Humeral Fractures with Pre-Contoured Locking Compression Plate

Anatomically precontoured locking plates are intended to facilitate the fixation of articular fractures and particularly those associated with osteoporosis. Fractures of the distal humerus are relatively uncommon injuries where operative intervention can be exceptionally challenging. The distal humeral trochlea provides a very narrow anatomical window through which to pass a fixed-angle locking...

متن کامل

Isolated Buttress Plating of Posterior Wall Acetabular Fractures: Is it Sufficient?

Background: Conventional fixation methods of posterior wall acetabular fractures feature the use of plating and lagscrews. However, fixation of posterior wall fractures with buttress plating alone offers potential advantages by avoidingthe hardware complications related to hardware placement through the wall fragment. The purpose of this study wasto examine if buttress plating...

متن کامل

A nonlocking end screw can decrease fracture risk caused by locked plating in the osteoporotic diaphysis.

BACKGROUND Locking plates transmit load through fixed-angle locking screws instead of relying on plate-to-bone compression. Therefore, locking screws may induce higher stress at the screw-bone interface than that seen with conventional nonlocked plating. This study investigated whether locked plating in osteoporotic diaphyseal bone causes a greater periprosthetic fracture risk than conventional...

متن کامل

First Metatarsophalangeal Joint Arthrodesis: A Retrospective Comparison of Crossed-screws, Locking and Non-Locking Plate Fixation with Lag Screw

Background:Locking plate fixation is increasingly used for first metatarsophalangeal joint (MTP-I) arthrodesis. Still there is few comparable clinical data regarding this procedure. Methods:We retrospectively evaluated 60 patients who received an arthrodesis of the MTP-I between January 2008 and June 2010. With 20 patients each we performed a locking plate fixation with lag screw, arthrodesis w...

متن کامل

Union Following Biological and Rigid Fixations of Distal Tibia Extra-articular Fractures

Background: Distal tibia fractures are among the most common bony injuries, with a significant rate of nonunion anddelayed union. There are multiple methods for the management of distal tibia fractures. Among the plating methods,there are bridge plating and compression plating techniques. There is still a lack of evidence about whether one methodhas a higher rate of union than...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of foot and ankle surgery : official publication of the American College of Foot and Ankle Surgeons

دوره 55 3  شماره 

صفحات  -

تاریخ انتشار 2016