An integrated system for planning, navigation and robotic assistance for skull base surgery.

نویسندگان

  • Tian Xia
  • Clint Baird
  • George Jallo
  • Kathryn Hayes
  • Nobuyuki Nakajima
  • Nobuhiko Hata
  • Peter Kazanzides
چکیده

BACKGROUND We developed an image-guided robot system to provide mechanical assistance for skull base drilling, which is performed to gain access for some neurosurgical interventions, such as tumour resection. The motivation for introducing this robot was to improve safety by preventing the surgeon from accidentally damaging critical neurovascular structures during the drilling procedure. METHODS We integrated a Stealthstation navigation system, a NeuroMate robotic arm with a six-degree-of-freedom force sensor, and the 3D Slicer visualization software to allow the robotic arm to be used in a navigated, cooperatively-controlled fashion by the surgeon. We employed virtual fixtures to constrain the motion of the robot-held cutting tool, so that it remained in the safe zone that was defined on a preoperative CT scan. RESULTS We performed experiments on both foam skull and cadaver heads. The results for foam blocks cut using different registrations yielded an average placement error of 0.6 mm and an average dimensional error of 0.6 mm. We drilled the posterior porus acusticus in three cadaver heads and concluded that the robot-assisted procedure is clinically feasible and provides some ergonomic benefits, such as stabilizing the drill. We obtained postoperative CT scans of the cadaver heads to assess the accuracy and found that some bone outside the virtual fixture boundary was cut. The typical overcut was 1-2 mm, with a maximum overcut of about 3 mm. CONCLUSIONS The image-guided cooperatively-controlled robot system can improve the safety and ergonomics of skull base drilling by stabilizing the drill and enforcing virtual fixtures to protect critical neurovascular structures. The next step is to improve the accuracy so that the overcut can be reduced to a more clinically acceptable value of about 1 mm.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Hierarchical SLAM/GPS/INS Sensor Fusion with WLFP for Flying Robo-SAR's Navigation

In this paper, we present the results of a hierarchical SLAM/GPS/INS/WLFP sensor fusion to be used in navigation system devices. Due to low quality of the inertial sensors, even a short-term GPS failure can lower the integrated navigation performance significantly. In addition, in GPS denied environments, most navigation systems need a separate assisting resource, in order to increase the avail...

متن کامل

Robotic surgery for the sinuses and skull base: what are the possibilities and what are the obstacles?

PURPOSE OF REVIEW Robotic surgery in otolaryngology - head and neck surgery has become a valuable tool in certain anatomic approaches; however, its application in surgery of the paranasal sinuses and anterior skull base is still in an investigatory phase and requires further evaluation. RECENT FINDINGS Existing robotic surgical systems face particular limitations in their application at the s...

متن کامل

Experience with various 3-dimensional navigation systems in head and neck surgery.

OBJECTIVE To evaluate the benefits and difficulties encountered when using various 3-dimensional (3-D) navigation systems in head and neck procedures. DESIGN Five different navigation systems were used for preoperative planning and intraoperative 3-D navigation in procedures at the paranasal sinuses, the frontal and lateral skull bases, and the petrous bone. INTERVENTION Intraoperative 3-D ...

متن کامل

Non-invasive registration in computer assisted craniomaxillofacial surgery

Computer-assisted technology was initially developed to provide neurosurgeons with precise guidance during surgical procedures. Currently available systems with and without robotic navigation are in use for specific medical indications. Various intraoperative navigation systems are used assisting surgery of the head and neck, such as endoscopic treatment of skull base [Kr96] and paranasal sinus...

متن کامل

Improved ultrasound-based navigation for robotic drilling at the lateral skull base

Sensitive structures of the lateral skull base demand for robotic procedures a higher precision than provided by standard navigation systems relying on CT scans. Keystone of our multisensor approach to improve accuracy is the use of ultrasound for local navigation. In this study we compare two different ultrasound techniques to measure human skull bone in vitro: (A) the classic echo technique a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The international journal of medical robotics + computer assisted surgery : MRCAS

دوره 4 4  شماره 

صفحات  -

تاریخ انتشار 2008