Comparison of a modified double-lumen endotracheal tube with a single-lumen tube with enclosed bronchial blocker.

نویسندگان

  • J H Campos
  • D K Reasoner
  • J R Moyers
چکیده

This study compared the modified BronchoCath double-lumen endotracheal tube with the Univent bronchial blocker to determine whether there were objective advantages of one over the other during anesthesia with one-lung ventilation (OLV). Forty patients having either thoracic or esophageal procedures were randomly assigned to one of two groups. Twenty patients received a left-side modified BronchoCath double-lumen tube (DLT), and 20 received a Univent tube with a bronchial blocker. The following were studied: 1) time required to position each tube until satisfactory placement was achieved; 2) number of times that the fiberoptic bronchoscope was required; 3) frequency of malpositions after initial placement with fiberoptic bronchoscopy; 4) time required until lung collapse; 5) surgical exposure ranked by surgeons blinded to type of tube used; and 6) cost of tubes per case. No differences were found in: 1) time required to position each tube (DLT 6.2 +/- 3.1 versus Univent 5.4 +/- 4.5 min [mean +/- SD]); 2) number of bronchoscopies per patient (DLT median 2, range 1-3 versus Univent median 3, range 2-5); or 3) time to lung collapse (DLT 7.1 +/- 5.4 versus Univent 12.3 +/- 10.5 min). The frequency of malposition was significantly lower for the DLT (5) compared to the Univent (15) (P < 0.003). Blinded evaluations by surgeons indicated that 18/20 DLT provided excellent exposure compared to 15/20 for the Univent group (P = not significant). We conclude that in spite of the greater frequency of malposition seen with the Univent, once position was corrected adequate surgical exposure was provided. In the Univent group the incidence of malposition and cost involved were both sufficiently greater that we cannot find cost/ efficacy justification for routine use of this device.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Papworth BiVent tube: a feasibility study of a novel double-lumen endotracheal tube and bronchial blocker in human cadavers.

BACKGROUND A novel double-lumen endotracheal tube, the Papworth BiVent tube, has been designed to allow the rapid passage of a blocker into either main bronchus, without fibreoptic endoscopic guidance. METHODS The feasibility of lung isolation and one-lung ventilation (OLV) in human cadavers is examined, along with displacement of the bronchus blocker during head and neck movement. RESULTS ...

متن کامل

Double-lumen endotracheal tube for one-lung ventilation through a fresh tracheostomy stoma: a case report.

For one-lung ventilation in many surgical cases, double-lumen endotracheal tubes are the first-line choice for airway management. For most cases, double-lumen endotracheal tubes are faster, easier to place, cheaper, and less prone to malposition than today's bronchial blocker devices. This report describes an elective tracheostomy and the use of a double-lumen endotracheal tube directly through...

متن کامل

Airway injuries after one-lung ventilation: a comparison between double-lumen tube and endobronchial blocker: a randomized, prospective, controlled trial.

BACKGROUND Vocal cord injuries, postoperative hoarseness, and sore throat are common complications after general anesthesia. One-lung ventilation can be achieved via two techniques: double-lumen endotracheal tube or endobronchial blocker such as the Arndt blocker. The current study was designed to assess the impact of these techniques for one-lung ventilation on the incidence and severity of po...

متن کامل

Lung Separation in the Morbidly Obese Patient

Lung separation techniques in the morbidly obese patient undergoing thoracic or esophageal surgery may be at risk of complications during airway management. Access to the airway in the obese patient can be a challenge because they have altered airway anatomy, including a short and redundant neck, limited neck extension and accumulation of fat deposition in the pharyngeal wall contributing to di...

متن کامل

[Selective lobar blockade with a Coopdech blocker combined with a double-lumen endotracheal tube for lung metastases resection by laser].

In recent years, laser resection of lung metastases has been established as the standard procedure worldwide. To avoid airway fire, it is necessary to collapse the surgical lung. The selective lobar bronchial blockade is a technique that allows one-lung ventilation while the operated lobe is collapsed in patients with previous pulmonary resection requiring subsequent resection or with limited p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Anesthesia and analgesia

دوره 83 6  شماره 

صفحات  -

تاریخ انتشار 1996