Diffusion Pore Imaging
نویسندگان
چکیده
Nuclear magnetic resonance (NMR) diffusion measurements are widely used to derive parameters indirectly related to the microstructure of biological tissues and porous media. However, a direct imaging of cell or pore shapes and sizes would be of high interest. For a long time, determining pore shapes by NMR diffusion acquisitions seemed impossible, because the necessary phase information could not be preserved. Here we demonstrate experimentally using the measurement technique which we have recently proposed theoretically that the shape of arbitrary closed pores can be imaged by diffusion acquisitions, which yield the phase information. For this purpose, we use hyperpolarized xenon gas in well-defined geometries. The signal can be collected from the whole sample which mainly eliminates the problem of vanishing signal at increasing resolution of conventional NMR imaging. This could be used to non-invasively gain structural information inaccessible so far such as pore or cell shapes, cell density or axon integrity.
منابع مشابه
Novel anisotropic MRI diffusion phantom
Diffusion MRI (DMRI) comprises a growing list of methods, and with that the need for a reliable and robust MRI phantom with which one can calibrate and validate them. In this study we developed a novel anisotropic diffusion MRI phantom and demonstrated its applicability by producing fractional anisotropy (FA) maps derived from DTI and average pore diameter maps using double Pulsed Field Gradien...
متن کاملPore diameter mapping using double pulsed-field gradient MRI and its validation using a novel glass capillary array phantom.
Double pulsed-field gradient (d-PFG) MRI can provide quantitative maps of microstructural quantities and features within porous media and tissues. We propose and describe a novel MRI phantom, consisting of wafers of highly ordered glass capillary arrays (GCA), and its use to validate and calibrate a d-PFG MRI method to measure and map the local pore diameter. Specifically, we employ d-PFG Spin-...
متن کاملTortuosity measurement and the effects of finite pulse widths on xenon gas diffusion NMR studies of porous media.
We have extended the utility of NMR as a technique to probe porous media structure over length scales of approximately 100-2000 microm by using the spin 1/2 noble gas 129Xe imbibed into the system's pore space. Such length scales are much greater than can be probed with NMR diffusion studies of water-saturated porous media. We utilized Pulsed Gradient Spin Echo NMR measurements of the time-depe...
متن کاملP27 Calibrating d-PFG Filtered MRI Using a Novel Anisotropic Diffusion Phantom
Diffusion Phantom Michal Komlosh 1, Evren Ozarslan 1, Martin Lizak 1, Ferenc Horkay 1, Peter Basser 1 1 National Institute of Health Introduction: Diffusion MRI methods can provide valuable microstructural in formation about tissues and porous media within an imaging volume [1-3], how ever, calibrating them is problematic owing to the lack of suitable anisotropic diffusion MRI phantoms. Here ...
متن کاملDiffusion pore imaging with generalized temporal gradient profiles.
In porous material research, one main interest of nuclear magnetic resonance diffusion (NMR) experiments is the determination of the shape of pores. While it has been a longstanding question if this is in principle achievable, it has been shown recently that it is indeed possible to perform NMR-based diffusion pore imaging. In this work we present a generalization of these previous results. We ...
متن کامل