Visual performance with simultaneous vision multifocal contact lenses.
نویسندگان
چکیده
PURPOSE The aim was to assess visual performance after PureVision high addition multifocal contact lens (PM) fitting through contrast sensitivity measured under different illumination levels for both distance and near. METHODS In a cross-over study, 20 presbyopic patients were randomly assigned to PM or spectacles. Near contrast sensitivity was measured with the Vistech VCTS 6500 system. Distance contrast sensitivity and distance visual acuity (VA) were measured with the Functional Vision Analyser under photopic (85 cd/m(2) ) and mesopic (3.0 cd/m(2) ) conditions, the latter also under two levels of induced glare: 1.0 lux and 28 lux. Near VA was measured by logMAR charts under approximately 80 cd/m(2) luminance settings. RESULTS Average monocular spectacle corrected and PM VA were -0.02 ± 0.05 and 0.03 ± 0.05 logMAR for distance photopic, 0.16 ± 0.10 and 0.23 ± 0.07 logMAR for distance mesopic and -0.03 ± 0.05 and 0.05 ± 0.06 logMAR for near photopic, respectively. Average binocular spectacle corrected and PM VA were -0.05 ± 0.07 and -0.01 ± 0.03 logMAR for distance photopic, 0.10 ± 0.06 and 0.18 ± 0.05 logMAR for distance mesopic and -0.08 ± 0.06 and 0.02 ± 0.05 logMAR for near photopic, respectively. Statistically significant differences were found between the contrast sensitivity with the two types of correction for both distance and near, with spectacle correction being better in all cases. CONCLUSION PureVision multifocal contact lenses preserve good VA and good visual performance under real-life conditions.
منابع مشابه
Power profiles of multifocal contact lenses and their interpretation.
PURPOSE Many contact lens (CL) manufacturers produce simultaneous-image lenses in which power varies either smoothly or discontinuously with zonal radius. We present in vitro measurements of some recent CLs and discuss how power profiles might be approximated in terms of nominal distance corrections, near additions, and on-eye visual performance. METHODS Fully hydrated soft, simultaneous-imag...
متن کاملThrough-focus visual performance measurements and predictions with multifocal contact lenses
We measured high-contrast visual acuity (VA) and 12c/deg contrast sensitivity (CS) through-focus functions (TFF) of four eyes of four cyclopleged subjects in three conditions: naked eye, with a center-distance and center-near Proclear(R) multifocal addition 2D contact lens. In all conditions, an adaptive optics system statically compensated the astigmatism of the subject's eye alone. Multifocal...
متن کاملShort-term visual performance of soft multifocal contact lenses for presbyopia.
PURPOSE To compare visual acuity (VA), contrast sensitivity, stereopsis, and subjective visual performance of Acuvue® Oasys® for Presbyopia (AOP), Air Optix® Aqua Multifocal (AOMF), and Air Optix® Aqua Single Vision (AOSV) lenses in patients with presbyopia. METHODS A single-blinded crossover trial was conducted. Twenty patients with mild presbyopia (add ≤+1.25 D) and 22 with moderate/severe ...
متن کاملComparison of Visual Performance of Multifocal Intraocular Lenses with Same Material Monofocal Intraocular Lenses
PURPOSE To compare the visual performance of multifocal intraocular lenses (IOLs) and monofocal IOLs made of the same material. METHODS The subjects included patients implanted with either Tecnis® monofocal IOLs (ZA9003 or ZCB00) or Tecnis® multifocal IOLs (ZMA00 or ZMB00) bilaterally. We conducted a retrospective study comparing the two types of IOLs. The multifocal group included 46 patient...
متن کاملBilateral implantation of asymmetrical diffractive multifocal intraocular lenses.
OBJECTIVE To evaluate visual results after bilateral implantation of multifocal intraocular lenses (IOLs) with asymmetrical light distribution for the far and near focus. METHODS Twenty-nine patients underwent bilateral implantation of silicone-optic, foldable, diffractive IOLs in a prospective, 2-center, noncontrolled interventional study. Each patient had a distant-dominant multifocal IOL i...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical & experimental optometry
دوره 95 1 شماره
صفحات -
تاریخ انتشار 2012