Low-cost Microfluidic Emitters for Nano-electrospray Ionization-mass Spectrometry

نویسندگان

  • Andrea E. Kirby
  • Mais J. Jebrail
  • Hao Yang
  • Aaron R. Wheeler
چکیده

We report a new microfluidic emitter for nano-electrospray ionization mass spectrometry (nanoESI-MS), made from polyimide tape. In contrast to the conventional pulled glass capillary emitters typically used for nanoESI-MS, these new polyimide emitters are simple and inexpensive to make, and are disposable after a single use. Thus, sample contamination and clogging are never a problem when analyzing different samples. The new emitters have comparable performance to pulled glass emitters, and are applicable to a variety to sample types and volumes, with the advantages of low cost, ease of use, and disposability.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Folded emitters for nanoelectrospray ionization mass spectrometry.

Electrospray ionization (ESI) has revolutionized mass spectrometry (MS), providing a facile method for the ionization of macromolecules for analysis by mass. The development of nanoESI-MS has further extended the utility of ESI-MS, permitting the analysis of small-volume samples with enhanced sensitivity over conventional ESI-MS. Traditional nanoESI-MS experiments use pulled-glass capillary emi...

متن کامل

Characterization of microstructured fibre emitters: in pursuit of improved nano electrospray ionization performance.

Full-dimensional computational fluid dynamics (CFD) simulations are presented for nano electrospray ionization (ESI) with various emitter designs. Our CFD electrohydrodynamic simulations are based on the Taylor-Melcher leaky-dielectric model, and the volume of fluid technique for tracking the fast-changing liquid-gas interface. The numerical method is first validated for a conventional 20 μm in...

متن کامل

A conductive polymeric material used for nanospray needle and low-flow sheathless electrospray ionization applications.

A conductive polypropylene/graphite mixture is used for the production of polymeric nanospray needle emitters and as a coating on fused-silica capillaries that are used for sheathless electrospray ionization (ESI). The described production of these polymeric nanospray needle emitters and sheathless ESI contacts is exceptionally easy and at a very low cost. The described polymeric nanospray emit...

متن کامل

A Reliable and Simple Method for Fabricating a Poly(Dimethylsiloxane) Electrospray Ionization Chip with a Corner-Integrated Emitter

Monolithically integrated emitters have been increasingly applied to microfluidic devices that are coupled to mass spectrometers (MS) as electrospray ionization sources (ESI). A new method was developed to fabricate a duplicable structure which integrated the emitter into a poly(dimethylsiloxane) chip corner. Two photoresist layers containing a raised base which guaranteed the precise integrati...

متن کامل

Microfabricated monolithic multinozzle emitters for nanoelectrospray mass spectrometry.

Mass spectrometry is the enabling technology for proteomics. To fully realize the enormous potential of lab-on-a-chip in proteomics, a major advance in interfacing microfluidics with mass spectrometry is needed. Here, we report the first demonstration of monolithic integration of multinozzle electrospray emitters with a microfluidic channel via a novel silicon microfabrication process. These mi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010