Letter to the editor: Novel indication for posterior dynamic stabilization: correction of disc tilt after lumbar total disc replacement
نویسندگان
چکیده
Cheng et al 1 have discussed using a dynamic posterior stabilization device to treat asymmetric collapse of an artificial disc in the coronal plane. Although this may correct the radiographic coronal-plane abnormality, there are significant biomechanical considerations to be kept in mind. When using these 2 devices in conjunction with each other at the same motion segment, the degrees of freedom and the center of rotation for both devices may not match and will act independently. This mismatch in the center of rotation can cause competitive domination between the 2 systems and result in early failures of the surrounding tissue and/or 1 or both fixation systems, contributing to compromised stability or progressive degeneration of the motion segment. Furthermore, multiple biomaterials and motion-enabling components have been incorporated into the design of posterior dynamic stabilization devices to allow for constrained , semiconstrained, or unconstrained motion across a motion segment. However, these design additions consist of various biomaterials with different elastic moduli or variations in subcomponent mechanisms that allow for applied limited motion, which may result in different overall mechanical performance for each fixation system. Polymeric materials are used in motion-enabling implants to provide a gradual, attenuated stopping mechanism of the dynamic implant, which in essence dampens the motion and lowers the stress transfer to the surrounding tissues. When metallic stopping mechanisms are integrated into the implant for a controlled motion, there is no atten-uation of the applied motion at these " hard stops, " thus causing repetitive impact forces at the metal interfaces. These repetitive impact loads may result in detrimental stress transfers to the local and adjacent surrounding tissues and early failure of the implant components, contributing to eventual loss of fixation across the motion segment and the potential for augmented degeneration of local and adjacent segments, In addition, there are competitive differences between the 2 device types when reaching the terminal endpoints of motion for all planes, such that the dampening effect for each implant will differ and cause abnormal force transfer between the 2 devices and loosening of either or both devices. Essentially, the devices will compete for control during the physiologic range of motion. The biome-chanics of such combinations need to be further investigated. Combined posterior and interbody motion-sparing devices have been designed with matched centers of rotation and final physiologic endpoints and have been used, although no long-term results are available. Hence, at this point, fusion of …
منابع مشابه
Novel indication for posterior dynamic stabilization: Correction of disc tilt after lumbar total disc replacement
BACKGROUND The increase in total disc replacement procedures performed over the last 5 years has increased the occurrence of patients presenting with postoperative iatrogenic deformity requiring revision surgery. Proposed salvage treatments include device retrieval followed by anterior lumbar interbody fusion or posterior fusion. We propose a novel approach for the correction of disc tilt after...
متن کاملResponse to editorial regarding a novel surgical treatment option in which posterior dynamic stabilization is used to correct coronal plane tilt of a lumbar total disc replacement
Response to editorial regarding a novel surgical treatment option in which posterior dynamic stabilization is used to correct coronal plane tilt of a lumbar total disc replacement We recently described a novel surgical treatment option in which posterior dynamic stabilization (PDS) is used to correct coronal plane tilt of a lumbar total disc replacement (TDR). 1 Clinical and radiographic outcom...
متن کاملPosterior Transpedicular Dynamic Stabilization versus Total Disc Replacement in the Treatment of Lumbar Painful Degenerative Disc Disease: A Comparison of Clinical Results
Study Design. Prospective clinical study. Objective. This study compares the clinical results of anterior lumbar total disc replacement and posterior transpedicular dynamic stabilization in the treatment of degenerative disc disease. Summary and Background Data. Over the last two decades, both techniques have emerged as alternative treatment options to fusion surgery. Methods. This study was co...
متن کاملDynamic stabilization of the lumbar spine.
This study analyzed the outcome of patients treated with total disk replacement and posterior dynamic stabilization. For pathologies of different origin, dynamic stabilization of the lumbar spine is a novel alternative to fusion surgery. Although a physiological reconstruction of the sagittal profile was not always achieved, improvement was seen in all subscales of the clinical outcome measures...
متن کاملA Rehabilitation Protocol for Patients with Lumbar Degenerative Disc Disease Treated with Posterior Transpedicular Dynamic Stabilization.
AIM To evaluate the efficacy of the rehabilitation protocol on patients with lumbar degenerative disc disease after posterior transpedicular dynamic stabilization (PTDS) surgery. MATERIAL AND METHODS Patients (n=50) with single level lumbar degenerative disc disease were recruited for this study. Patients had PTDS surgery with hinged screws. A rehabilitation program was applied for all patien...
متن کامل