It all unraveled from there: case report of a central venous catheter guidewire unraveling.
نویسندگان
چکیده
BACKGROUND Inferior vena cava (IVC) filters can present challenges to emergency physicians in the process of central venous catheter (CVC) placement. CASE REPORT A 68-year-old woman presented to the emergency department with severe shortness of breath and was intubated. A central line was placed after the intubation to facilitate peripheral access. A CVC guidewire unraveled during placement after getting caught on an IVC filter. WHY SHOULD AN EMERGENCY PHYSICIAN BE AWARE OF THIS?: Emergency physicians should be aware of the complications that IVC filters can cause in the placement of CVCs. Imaging and identification of IVC filters beforehand will allow for proper planning of how to manage the case in which a filter catches on the guidewire. Simple anecdotal techniques, such as advancing the guidewire and spinning the guidewire between the fingers, can facilitate the removal of the guide wire from the IVC filter.
منابع مشابه
Guidewire-Related Complications during Central Venous Catheter Placement: A Case Report and Review of the Literature
Seldinger's technique is widely used to place central venous and arterial catheters and is generally considered safe. The technique does have multiple potential risks. Guidewire-related complications are rare but potentially serious. We describe a case of a lost guidewire during central venous catheter insertion followed by a review of the literature of this topic. Measures which can be taken t...
متن کاملAbdominal pain due to a lost guidewire: a case report
A lost guidewire is a hazardous, yet completely preventable, and rare complication associated with central venous catheter insertion. Here, we report a case of a lost guidewire in a patient presented with persistent abdominal pain. The guidewire was retrieved completely during a surgical operation after the diagnosis had been confirmed by radiologic studies. Following some tips during insertion...
متن کاملFracture of J-tipped guidewire during central venous catheterization and its successful removal under fluoroscopic guidance -A case report-
Central venous catheterization by Seldinger's technique uses a guidewire which may cause complications such as kinking, knotting and fracture. Fractured guidewire may lead to severe outcomes such as embolization, and removal of it may also cause problems such as vessel damage. We experienced a case of right internal jugular venous catheterization complicated by guidewire fracture entrapped in t...
متن کاملSuccessful removal of kinked J-guide wire under fluoroscopic guidance during central venous catheterization -A case report-
Guidewire-associated complications that occur during the process of central venous catheterization include its kinking, looping, knotting and breakage. The removal of a looped or knotted guidewire is problematic because it can cause vessel damage, major hemorrhage, or embolization of a fractured guidewire. We report a case of guidewire kinking and its successful removal under fluoroscopic guida...
متن کاملAn unusual route taken by a central venous catheter resulting in inadvertent subclavian artery cannulation: a case report
Ultrasound-guided cannulation of a central venous catheter into the internal jugular vein (IJV) was performed in the intensive care unit for a critically ill patient. The catheter was inserted into the subclavian artery distally, despite prior ultrasound confirmation of the guidewire position using both the in-plane and out-of-plane views. The catheter was removed successfully by the interventi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of emergency medicine
دوره 47 6 شماره
صفحات -
تاریخ انتشار 2014