Lens siderosis resulting from a tiny missed intralenticular foreign body.
نویسندگان
چکیده
We report a patient with clinical ocular siderosis at the time of presentation but undetectable intraocular foreign body on computed tomography (CT) and ultrasonography. A 24-year-old man suffered from right ocular injury when hammering metal on metal. Slit-lamp examination revealed a small corneal perforating wound and an iris hole, but no intraocular foreign body was found under fundus examination. There was also no evidence of intraocular foreign body on ultrasonography and orbital CT scan. About 1 month later, lens siderosis with cataract formation developed, and the patient received lens extraction with intraocular lens implantation. During the operation, a small (< 1 x 1 x 1 mm in size) intralenticular foreign body of metal material was found and removed. The patient's visual acuity improved from 6/20 to 6/6 on the next day. A patient suspected to have intraocular foreign body should be followed-up closely; it is better to remove the foreign body before siderosis bulbi occurs.
منابع مشابه
Lens siderosis resulting from a small intralenticular metallic foreign body
We report a rare case of lens siderosis with an undetectable intraocular foreign body by imaging. An 8-year-old boy presented with diminution of vision in the left eye since 3 months. His parents gave a preceding uncertain history of a foreign body injury to his left eye 3 months ago while playing. Presenting visual acuity in the left eye was perception of hand movements. Slit-lamp examination ...
متن کاملIntracapsular Extraction of Intralenticular Magnetic Foreign Bodies.
INTRALENTICULAR magnetic foreign bodies if left untreated lead in most instances to total cataract formation, siderosis, or as a later complication, loss of the eye. Since the use of the magnet has been developed, and powerful hand instruments have made manipulation easier, intralenticular magnetic foreign bodies have been removed by this means via the anterior route. The risk of siderosis is t...
متن کاملA case of a retained intralenticular foreign body for two years
We report a case of a missed metallic intraocular foreign body retained in the lens over a two-year period without causing inflammatory reaction, which presented with cataract later. A 24-year-old man presented with a progressive blurring of vision in the left eye for two years. He had had a history of metal-on-metal activity two years before. He had pain for one day in left eye and it was heal...
متن کاملLong-standing Asymptomatic Intralenticular Foreign Body
Dear Editor, Intralenticular foreign bodies are uncommon after penetrating eye injuries, occurring in approximately 5% to 10% of cases [1]. They generally present with a decrease in visual acuity resulting from aggravation of a traumatic cataract. In Korea, there has been only one previous report of an intralenticular foreign body, which was retained for 6 months [2]. Several previous reports d...
متن کاملIntralenticular Foreign Body: A Case Report And Review of the Literature
Intraocular foreign body constitutes the 18-41% of penetrating eye injuries. Ten percent of these are localized intralenticularly. Depending on the severity of the trauma and the degree of the disruption of the structural integrity of the lens capsule, crystalline lens can lose its transparency and cataract surgery is needed. Metallic foreign bodies are observed most frequently. In case of iner...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of the Chinese Medical Association : JCMA
دوره 72 1 شماره
صفحات -
تاریخ انتشار 2009