An In-vitro Comparison of Force Loss of Orthodontic Non-Latex Elastics
نویسندگان
چکیده
OBJECTIVE The amount and consistency of the applied forces to the tooth are important factors in tooth movements; therefore, the aim of this study was to compare the initial force and the force loss of three brands of elastics in 24 hours. MATERIALS AND METHODS In this in-vitro study sixty non-latex elastics (3/16 medium) from three companies (Forestadent, Dentaurum and Ortho Technology) were randomly selected. Two static tests were performed, the first in a dry environment to evaluate the initial force and the other performed in a wet environment (artificial saliva) to evaluate the force loss in 24 hours. The Universal testing machine measured the forces after stretching the elastics to three times the lumen diameter. Data were analyzed by repeated measures ANOVA, One-way ANOVA, Tukey-HSD, Paired samples test, and one sample test. RESULTS The difference between the brands was significant (p=0.002). Force loss was observed in all samples; 4-7.5% force loss occurred after one hour and 19-38% force loss occurred after 24 hours. The average initial force of Forestadent and Ortho Technology was significantly higher than marketed forces (p<0.001), but the initial force of Dentaurum elastics was similar to the marketed force. CONCLUSION The force loss over 24 hours time period was Forestadent>Dentaurum>Ortho-Technology. According to the initial force and force loss percentage it is suggested to replace the non-latex elastics several times a day.
منابع مشابه
Elasticity in Elastics-An in-vitro study.
BACKGROUND Orthodontic tooth movement results from application of forces to teeth. Elastics in orthodontics have been used both intra-orally and extra- orally to a great effect. Their use, combined with good patient co-operation provides the clinician with the ability to correct both anteroposterior and vertical discrepancies. Force decay over a period of time is a major problem in the clinical...
متن کاملIn vitro study of force decay of latex and non-latex orthodontic elastics.
The aim of this study was to evaluate the force decay of two brands of orthodontic elastics, both offering latex and non-latex products. Samples were subjected to continuous stretching, measuring force at 5 seconds, 8 hours, and 24 hours in both dry and wet conditions. Five hundred samples were used, GAC® and Lancer® 0.25 inch and 4 oz, divided into testing sample sizes of n = 25 per group. For...
متن کاملLatex and non-latex orthodontic elastic force loss due to cyclic temperature.
UNLABELLED The purpose of this study was to compare the force loss of 1/4 inch (6.35mm) 3.5oz (99g) medium latex elastics from Ormco Corp. to non-latex elastics from ClassOne Orthodontics and Phoenix after being cycled between different temperatures. Elastics were stretched to 1.57 inches (40mm) on jigs and cycled in water baths for 4 minutes at 5 degrees C and 37 degrees C, 21 degrees C and 37...
متن کاملForce Relaxation Characteristics of Medium Force Orthodontic Latex Elastics: A Pilot Study
To evaluate force extension relaxation of different brands and diameters of latex elastics subjected to static tensile testing under an apparatus designed to simulate oral environments, sample sizes of 5 elastics from American Orthodontics (AO), Tp, and Morelli Orthodontics (Mo) of equivalent medium force, (3/16, 1/4, and 5/16 inch size) were tested. The forces were read after 1-, 3-, 6-, 12- a...
متن کاملEvaluation of the cytotoxicity of latex and non-latex orthodontic separating elastics.
OBJECTIVE To test the hypothesis that a difference in cytotoxicity exists between latex and non-latex orthodontic separating elastics. MATERIAL AND METHODS Five intra-oral separating elastics from different manufactures (four latex and one non-latex) were divided into five groups of 15 elastics each: Group MA (non-latex elastics, Masel), Group MO (natural latex, Morelli), Group DE (natural la...
متن کامل