Differentiation between gaseous and formed embolic materials in vivo. Application in prosthetic heart valve patients.

نویسندگان

  • D Georgiadis
  • T G Mackay
  • A W Kelman
  • D G Grosset
  • D J Wheatley
  • K R Lees
چکیده

BACKGROUND AND PURPOSE Doppler emboli detection is an established technique, but the nature of the underlying embolic material remains unclear. The intensity and spectral distribution of emboli signals could help to distinguish between signals arising from formed and gaseous emboli. We undertook this study to develop and evaluate a differentiation algorithm based on the spectral characteristics of emboli signals. Subsequently the algorithm was applied to patients with mechanical prosthetic cardiac valves. METHODS Emboli signals detected in patients with carotid disease, acute stroke, and atrial fibrillation were used as formed emboli data, and signals detected in patients undergoing cardiac catheterization studies were used as gaseous emboli data. For each embolus signal, the maximal amplitude, the sum of amplitudes, and the spectral intensity distribution were calculated. Two hundred emboli signals from each category were used to develop a differentiation algorithm, which was subsequently evaluated on 501 additional solid and 995 gaseous emboli signals. The same algorithm was used to analyze 5958 emboli signals detected in 60 patients with mechanical prosthetic valves. RESULTS The best results were obtained with an algorithm based on both the maximal amplitude and the sum of amplitudes (sensitivity, 99%; specificity, 96.5%). On subsequent evaluation, the sensitivity and specificity of the algorithm were 99.6% and 89.8%, respectively. Of the 5958 emboli signals detected in prosthetic valve patients, 92.4% were classified as gaseous. CONCLUSIONS Differentiation between gaseous and formed emboli signals, as detected by transcranial Doppler in vivo, is feasible by means of spectral analysis. Application of the differentiation algorithm in prosthetic valve patients suggests that the embolic material in these patients is gaseous. The possibility of distinguishing between different formed embolic materials with this technique remains to be evaluated.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transcranial Doppler application for risk assessment of stroke in patients with mechanical mitral valve

Introduction: Observing microembolic signals in brain vessels by transcranial Doppler technology is a very common finding in patients with mechanical heart valve. These signals are almost always clinically asymptomatic. The aim of this study was assessment of transcranial Doppler in detecting probability of stroke in patients with mechanical heart valve. Methods: This descriptive study was ca...

متن کامل

Prosthetic valve endocarditis caused by multidrug-resistant Candida albicans in a patient with myelodysplasia syndrome: A case report and literature review

Background and Purpose: Candida endocarditis is an infrequent disease with a high mortality rate, which commonly occurs in immunosuppressed patients with cardiac valve replacement. We reported a 70-year-old woman diagnosed with Candida prosthetic valve endocarditis (PVE). This study also involved a review of all published cases of Candida PVE from 1970. Case report: Herein, we reported a 70-ye...

متن کامل

Online automatic discrimination between solid and gaseous cerebral microemboli with the first multifrequency transcranial Doppler.

BACKGROUND AND PURPOSE The aim of this study was to assess the first multifrequency transcranial Doppler system that was specially developed to automatically detect and discriminate between solid and gaseous cerebral microemboli. METHODS The multifrequency transcranial Doppler instrumentation insonates simultaneously with 2.5 and 2.0 MHz. Differentiation between solid and gaseous microemboli ...

متن کامل

Transcranial Doppler Detection of Circulating Cerebral Emboli

Background: The identification of gaseous emboli using Doppler ultrasound was described as early as the 1960s. Recently it has been demonstrated that this method can also detect solid emboli such as thrombi and platelet aggregates. This may make this technology useful in a large number of patients with, or at risk of, embolic stroke. Summary of Review: Emboli appear as short-duration, high-inte...

متن کامل

Transcranial Doppler Detection of Circulating Cerebral Emboli

Background: The identification of gaseous emboli using Doppler ultrasound was described as early as the 1960s. Recently it has been demonstrated that this method can also detect solid emboli such as thrombi and platelet aggregates. This may make this technology useful in a large number of patients with, or at risk of, embolic stroke. Summary of Review: Emboli appear as short-duration, high-inte...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Stroke

دوره 25 8  شماره 

صفحات  -

تاریخ انتشار 1994