First experience with the new high-frequency femtosecond laser system (LDV Z8) for cataract surgery
نویسندگان
چکیده
BACKGROUND The purpose of this work is to report our experience using the new Z8 laser system for femtosecond laser-assisted cataract surgery (FLACS) and to provide a sample of the performance and safety results using this new technology. METHODS This prospective observational study was performed at the Swiss Eye Research Foundation, Eye Clinic ORASIS, Reinach, Switzerland. Fourteen patients were subjected to unilateral FLACS. Capsulotomy and lens fragmentation were performed with the aid of the LDV Z8 femtosecond laser system. Ease of phacoemulsification (on a 4-point scale), completeness of capsulotomy (on a 10-point scale), time for preparation of femtosecond laser (minutes), effective phacoemulsification time (seconds), total duration of surgery (minutes), and safety of the procedure were evaluated. RESULTS Ease of fragmentation and completeness of capsulotomy were estimated at 3.9 and 9.9, respectively. The preparation time for femtosecond was 3.6±0.7 minutes, effective phacoemulsification time was 2.5±3.1 seconds, and total duration of the FLACS procedure was 16.3±4.5 minutes. No major complications were observed. Approximately 42% of all patients (6/14) showed Descemet's folds directly postoperatively. CONCLUSION FLACS with the LDV Z8 system was characterized by complete capsulotomy and highly effective and reproducible lens fragmentation. The safety of the procedure was very good as perceived by the surgeon operating in this observational case series. The cost to benefit ratio should be further debated by assessing the results of a major prospective study, which is required for valid evaluation of the efficiency and safety of the LDV Z8 laser system and of FLACS in general.
منابع مشابه
Cataract Surgery Performed by High Frequency LDV Z8 Femtosecond Laser: Safety, Efficacy, and Its Physical Properties
BACKGROUND The aim of our study was to investigate the safety and efficacy of the LDV Z8 femtosecond laser in cataract surgery compared to the conventional procedure. METHODS This prospective study was performed at the Swiss Eye Research Foundation, Eye Clinic ORASIS, Reinach, Switzerland. The study included 130 eyes from 130 patients: 68 treated with femtosecond laser-assisted cataract surge...
متن کاملComparison of intra-ocular pressure changes with liquid or flat applanation interfaces in a femtosecond laser platform
Cataract surgery is the most common surgical procedure and femtosecond laser assisted cataract surgery (FLACS) has gained increased popularity. FLACS requires the application of a suction device to stabilize the laser head and focus the laser beam accurately. This may cause a significant escalation in intra-ocular pressure (IOP), which poses potential risks for patients undergoing cataract surg...
متن کاملThe effects of a low-energy, high frequency liquid optic interface femtosecond laser system on lens capsulotomy
The introduction of femtosecond laser assisted cataract surgery (FLACS) is a paradigm changing approach in cataract surgery, the most commonly performed surgical procedure. FLACS has the potential to optimize the creation of an anterior lens capsulotomy, a critical step in accessing the cataractous lens. The merits of using a laser instead of a manual approach include a potentially more circula...
متن کاملA Comparison of Different Operating Systems for Femtosecond Lasers in Cataract Surgery
The introduction of femtosecond lasers is potentially a major shift in the way we approach cataract surgery. The development of increasingly sophisticated intraocular lenses (IOLs), coupled with heightened patient expectation of high quality postsurgical visual outcomes, has generated the need for a more precise, highly reproducible and standardized method to carry out cataract operations. As f...
متن کاملPerforming Reliable Lens Capsulotomy in the Presence of Corneal Edema With a Femtosecond Laser.
Purpose To determine the effects of the Ziemer LDV Z8 liquid interface femtosecond laser platform during capsulotomy under different energy settings in the presence of corneal edema. Methods Cadaveric porcine eyes (n = 36) employed at less than 6 and greater than 24 post enucleation hours to simulate clear/edematous corneas, underwent capsulotomy with the Ziemer LDV Z8 femtosecond laser (5-mm...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 8 شماره
صفحات -
تاریخ انتشار 2014