Pii: S1010-7940(02)00121-5

نویسندگان

  • J. Reis
  • J. C. Mota
  • P. Ponce
  • A. Costa-Pereira
  • M. Guerreiro
چکیده

Background: With the evolution of anesthesia and surgical procedures, fast track extubation has gained an increased interest, mainly based on the possibility of reducing health costs seemingly without compromising patient care. Aim: To compare two groups of patients submitted to a non-fast track extubation and a fast track extubation protocol after coronary artery bypass graft surgery with cardiopulmonary bypass, regarding their times of ventilation and intubation and their complication rates in the postoperative period. Methods: During the year of 1998, 323 sequential patients scheduled for isolated coronary artery bypass graft surgery with cardiopulmonary bypass were enrolled in the study. Fifty-nine patients were excluded due to preoperative use of emergent mechanical and/or inotropic hemodynamic support, low body mass index (#18–20 kg/m), reoperations for acute surgical complications, off-pump coronary artery bypass graft surgery, severe respiratory disease, recent myocardial infarction (#7 days) and absence of relevant data. Previous myocardial infarction ($7 days), prophylactic intraaortic balloon pump and use of postoperative vasoactive drugs were not exclusion criteria. We compared 76 patients sequentially submitted to anesthesia by one of the authors with a fast track extubation protocol and 188 patients sequentially submitted to anesthesia by others in the same period and using a conventional anesthetic protocol. Results: Demographic data, previous medical and cardiac history, preoperative medication and operative data were all similar between the two groups. The mean ventilation and intubation times were significantly shorter in the fast track extubation group than in the non-fast track extubation patients (30 min vs. 7 h and 50 min vs. 8 h, respectively). Forty-two percent of patients in the fast track extubation group were extubated on arrival at the intensive care unit. Morbidity and mortality were similar in both groups. Conclusions: The study shows that a very fast track extubation protocol may be safely implemented in patients submitted to coronary artery bypass graft surgery with cardiopulmonary bypass. q 2002 Elsevier Science B.V. All rights reserved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pii: S1010-7940(02)00020-9

Electrocautery has a potential risk of serious pacemaker dysfunction in patients with implanted pacemaker. Here we present the safe and efficient use of ultrasonic scalpel (Harmonic scalpel) for the first time in a patient with implanted pacemaker undergoing open-heart reoperation. q 2002 Elsevier Science B.V. All rights reserved.

متن کامل

Pii: S1010-7940(02)00664-4

This report describes the formation of a true aneurysm 15 years after an internal mammary artery patch aortoplasty of an aortic coarctation. A true aneurysm was confirmed on histology. To our knowledge, this is the first report of a case with such a complication. q 2002 Published by Elsevier Science B.V.

متن کامل

Pii: S1010-7940(02)00369-x

Lipomatous hypertrophy of the interatrial septum is an uncommon entity that usually occurs in elderly patients. We report a patient who presented with atrial fibrillation, congestive cardiac failure and a large intracavitary mass in the right atrium on echocardiography. He underwent successful resection of the mass with septal reconstruction. Pathology was consistent with lipomatous hypertrophy...

متن کامل

Pii: S1010-7940(02)00349-4

Arterial pseudoaneurysm has been reported as a possible complication of immunodeficiency virus infection. We report two cases of HIVpositive patients with a pseudoaneurysm at the level of the descending thoracic aorta. The first patient refused surgery and has been followed up to 14 months, whereas the second patient underwent successful surgical repair. The importance of magnetic resonance ima...

متن کامل

Pii: S1010-7940(02)00396-2

We present rupture of lung hydatid cyst in a patient with multiple organ involvement during albendazole treatment. The patient was first provided mechanical ventilation than residue cavity and the other intact cyst was treated surgically. We concluded that albendazole should be used in postoperative period in patients with hydatid disease of the lung to prevent recurrent disease. q 2002 Elsevie...

متن کامل

Pii: S1010-7940(02)00724-8

Aortobronchial fistula is a rare complication following thoracic aortic operations and is invariably fatal if not promptly diagnosed and repaired. Direct prosthetic repair carries a risk of graft repair sepsis and fistula recurrence. We describe two cases presenting with aortobronchial fistula following coarctation repair which were successfully treated by different surgical approaches. q 2002 ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2002