Resting radionuclide myocardial perfusion imaging in a chest pain center including an overnight delayed image acquisition protocol.

نویسندگان

  • Michael W Schaeffer
  • Timothy D Brennan
  • Judith A Hughes
  • W Brian Gibler
  • Myron C Gerson
چکیده

UNLABELLED Emergency department (ED) patients with chest pain (CP) and a nondiagnostic electrocardiogram (ECG) present difficult management decisions. The purpose of this study was to investigate the utility of resting radionuclide SPECT myocardial perfusion imaging (SPECT MPI)-including an overnight delayed image acquisition protocol-in identifying patients presenting to the ED with CP at risk for cardiac events. METHODS Patients presenting to the ED with CP and a nondiagnostic ECG were prospectively enrolled and underwent chest pain center evaluation. All patients also underwent resting gated SPECT MPI using (99m)Tc-tetrofosmin tracer. Patients presenting on weeknights between 12 am and 6 am had tracer injection in the ED with image acquisition delayed until later in the morning. Patients were monitored for a 30-d occurrence of cardiac events. RESULTS Over a 16-mo period, 479 patients were enrolled and completed follow-up. For the prediction of 30-d cardiac events, resting SPECT MPI demonstrated a sensitivity and a specificity of 76.9% and 92.4%, respectively. Positive and negative predictive values were 22.2% and 99.3%, respectively. Among the 3 patients with a normal perfusion scan who suffered cardiac events, all had tracer injection several hours after resolution of CP. The overnight delayed image acquisition protocol provided a negative predictive value of 100% for the 44 patients whose image acquisition was delayed until the following morning. CONCLUSION A normal resting SPECT MPI in ED patients presenting with CP predicts a very low occurrence of 30-d cardiac events. A delayed image acquisition protocol did not decrease the accuracy of SPECT MPI. Such a protocol may be useful in increasing the availability of this imaging modality.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Use of resting myocardial scintigraphy during chest pain to exclude diagnosis of acute myocardial infarction.

BACKGROUND Images of myocardial perfusion taken during an episode of chest pain have been used for patients in the emergency department. OBJECTIVE To evaluate the operating characteristics of 99mTc-Tetrofosmin scintigraphy during an episode of chest pain to exclude the diagnosis of acute myocardial infarction. METHODS One hundred and eight patients admitted with chest pain, or up to four ho...

متن کامل

Covid-19 manifestation on Tl-201 myocardial perfusion SPECT/CT

A 67 years old woman was referred to nuclear medicine center for myocardial perfusion imaging (MPI) for assessment of ischemic heart dieses (IHD).She had a history of atypical chest pain and dyspnea since about 10 days before admission. The MPI SPECT/CT was performed by stress/redistribution Tl-201 protocol. MPI was interpreted as relatively good coronary flow with no appreciable stress induced...

متن کامل

Myocardial Perfusion SPECT Imaging in Dextrocardia with Situs Inversus: A Case Report

Dextrocardia is a cardiac positional anomaly in which the heart is located in the right hemithorax with its base-to-apex axis directed to the right and caudad. Situs inversus is an autosomal recessive disorder that causes organs in the chest and abdomen to be positioned in a mirror image from their normal position. Dextrocardia may occur in isolation or as part of situs inversus. Similarly, sit...

متن کامل

Differential impact of multi-focus fan beam collimation with L-mode and conventional systems on the accuracy of myocardial perfusion imaging: Quantitative evaluation using phantoms

Objective(s): A novel IQ-SPECTTM method has become widely used in clinical studies. The present study compares the quality of myocardial perfusion images (MPI) acquired using the IQ-SPECTTM (IQ-mode),conventional (180° apart: C-mode) and L-mode (90° apart: L-mode) systems. We assessed spatial resolution, image reproducibility and quantifiability using various physical phantoms. Materials and Me...

متن کامل

Compensation of Cross-Contamination in Simultaneous 201Tl/99mTc Myocardial Perfusion SPECT Imaging

Introduction: It is a common protocol to use 201Tl for the rest and 99mTc for the stress cardiac SPECT imaging. Theoretically, both types of imaging may be performed simultaneously using different energy windows for each radionuclide. However, a potential limitation is the cross-contamination of scattered photons from 99mTc and collimator X-rays into the 201Tl energy window. We used a middle en...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine technology

دوره 35 4  شماره 

صفحات  -

تاریخ انتشار 2007