How to Sync to the Beat of a Persistent Fractal Metronome without Falling Off the Treadmill?
نویسندگان
چکیده
In rehabilitation, rhythmic acoustic cues are often used to improve gait. However, stride-time fluctuations become anti-persistent with such pacing, thereby deviating from the characteristic persistent long-range correlations in stride times of self-paced walking healthy adults. Recent studies therefore experimented with metronomes with persistence in interbeat intervals and successfully evoked persistent stride-time fluctuations. The objective of this study was to examine how participants couple their gait to a persistent metronome, evoking persistently longer or shorter stride times over multiple consecutive strides, without wandering off the treadmill. Twelve healthy participants walked on a treadmill in self-paced, isochronously paced and non-isochronously paced conditions, the latter with anti-persistent, uncorrelated and persistent correlations in interbeat intervals. Stride-to-stride fluctuations of stride times, stride lengths and stride speeds were assessed with detrended fluctuation analysis, in conjunction with an examination of the coupling between stride times and stride lengths. Stride-speed fluctuations were anti-persistent for all conditions. Stride-time and stride-length fluctuations were persistent for self-paced walking and anti-persistent for isochronous pacing. Both stride times and stride lengths changed from anti-persistence to persistence over the four non-isochronous metronome conditions, accompanied by an increasingly stronger coupling between these gait parameters, with peak values for the persistent metronomes. These results revealed that participants were able to follow the beat of a persistent metronome without falling off the treadmill by strongly coupling stride-length fluctuations to the stride-time fluctuations elicited by persistent metronomes, so as to prevent large positional displacements along the treadmill. For self-paced walking, in contrast, this coupling was very weak. In combination, these results challenge the premise that persistent metronomes in gait rehabilitation would evoke stride-to-stride dynamics reminiscent of self-paced walking healthy adults. Future studies are recommended to include an analysis of the interrelation between stride times and stride lengths in addition to the correlational structure of either one in isolation.
منابع مشابه
Persistent Fluctuations in Stride Intervals under Fractal Auditory Stimulation
Stride sequences of healthy gait are characterized by persistent long-range correlations, which become anti-persistent in the presence of an isochronous metronome. The latter phenomenon is of particular interest because auditory cueing is generally considered to reduce stride variability and may hence be beneficial for stabilizing gait. Complex systems tend to match their correlation structure ...
متن کاملEntrainment to a real time fractal visual stimulus modulates fractal gait dynamics.
Fractal patterns characterize healthy biological systems and are considered to reflect the ability of the system to adapt to varying environmental conditions. Previous research has shown that fractal patterns in gait are altered following natural aging or disease, and this has potential negative consequences for gait adaptability that can lead to increased risk of injury. However, the flexibili...
متن کاملQuantification of the relationships between volume and intensity of exhaustive treadmill running in active young men
ABSTRACT: Aim: Quantifying the relationship between volume and intensity as key components of training is a precise manner that is complicated for most coaches. The aim of this study was to quantify the inverse relationships between training volume and intensity during exhaustive treadmill running among active young men. Method and Material: 32 active young men aged 21 years selected as subjec...
متن کاملThe Global Metronome: Absolute Tempo Sync For Networked Musical Performance
At a time in the near future, many computers (including devices such as smart-phones) will have system clocks that are synchronized to a high degree (less than 1 ms of error). This will enable us to coordinate events across unconnected devices with a degree of accuracy that was previously impossible. In particular, high clock synchronization means that we can use these clocks to synchronize tem...
متن کاملOn The Behavior of Malaysian Equities: Fractal Analysis Approach
Fractal analyzing of continuous processes have recently emerged in literatures in various domains. Existence of long memory in many processes including financial time series have been evidenced via different methodologies in many literatures in past decade, which has inspired many recent literatures on quantifying the fractional Brownian motion (fBm) characteristics of financial time series. Th...
متن کامل