Lactate measured in diluted and undiluted whole blood and plasma: comparison of methods and effect of hematocrit.

نویسندگان

  • J Toffaletti
  • M E Hammes
  • R Gray
  • B Lineberry
  • B Abrams
چکیده

We evaluated a new analyzer that measures lactate in undiluted whole blood by direct (or undiluted) amperometry [Nova Stat Profile 7 Analyzer (SP7); Nova Biomedical, Waltham, MA] by comparing it with two other analyzers, one for measuring lactate in whole blood by indirect (or diluted) amperometry [Model 2300; Yellow Springs Instrument Co. (YSI), Yellow Springs, OH] and another for measuring lactate in plasma by enzymatic colorimetry (aca; Du Pont Co., Wilmington, DE). All between-method comparisons of the three methods showed that the results for plasma were comparable (Sy/x = 0.24-0.33 mmol/L). Within-method comparisons by the YSI differed substantially between plasma and whole blood (Sy/x = 0.48 mmol/L), but within-method comparisons by the SP7 produced better agreement between plasma and whole blood (Sy/x = 0.18 mmol/L). The difference between whole blood and plasma by YSI is related to hematocrit, with the greatest differences noted for samples with the highest hematocrit. Serum lactate measured by SP7 had between-day imprecision (CV) ranging from 12% at 0.5 mmol/L to 4.2% at 3.7 mmol/L, showed a linear standard curve to at least 11.5 mmol/L, and was independent of hematocrit. There was a mean bias of approximately 0.4 mmol/L for results in the reference range for both plasma and whole blood by SP7 compared with plasma results by either aca or YSI.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The response of plasma glucose, lactate, protein and hematological parameters to osmotic challenge in common carp (Cyprinuscarpio)

Fluctuations in salinity impose stress on the physiology of the exposed fish population and can modify their structure. It has been noted that changes in blood characteristics and plasma levels serve as the primary link between environmental change and physiological response (McCormick, 2001). Ninety healthy adult Cyprinuscarpio (C. carpio) were randomly divided into five groups and kept in sal...

متن کامل

The Alterations of Plasma Iipid Peroxidation and erythrocyte Superoxide Dismutase and Glutathione Peroxidase Enzyme Activities During Storage of Blood

Abstract Background and objective: Exposure of red blood cells to oxygen radicals can induce Lipid proxidation, hemoglobin damage and hemolysis of erythrocyte .The present study was designed to determine the alteration of plasma lipid peroxidation and erythrocyte Superoxide Dismutase and Glutathione Peroxidase enzyme activities in stored blood and to find out the quantitative alterations and th...

متن کامل

Comparison of the Effect of Voluven and Ringer Solution in Cardiopulmonary Bypass on the Bleeding After the Surgery and Renal Function in Coronary Artery Bypass Graft Surgeries

Background: This study compared the effect of Voluven and Ringer solution in cardiopulmonary bypass on the bleeding after the surgery and renal function in coronary artery bypass graft surgeries. Methods: Two types of prime solution including ringer - as Crystalloid- and Voluven were used in two groups and compared in terms of bleeding and renal function during the first 24 hours after the surg...

متن کامل

Computed exercise plasma lactate concentrations: A conversion formula

OBJECTIVES Blood lactate measurements are common as a marker of skeletal muscle metabolism in sport medicine. Due to the close equilibrium between the extracellular and intramyocellular space, plasma lactate is a more accurate estimate of muscle lactate. However, whole blood-based lactate measurements are more convenient in field use. The purpose of this investigation was therefore (1) to estab...

متن کامل

Improving lactate analysis with the YSI 2300 GL: hemolyzing blood samples makes results comparable with those for deproteinized whole blood.

To obviate the well-documented problem of hematocrit dependency of the Yellow Springs Instruments (YSI) whole-blood lactate analyzer, we modified the dilution buffer by including a lysing reagent. This makes the results comparable with those of methods performed with deproteinized whole-blood samples. No centrifugation step is needed, thus preserving the convenience of the YSI instrument for st...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 38 12  شماره 

صفحات  -

تاریخ انتشار 1992