Comparison of semi-automated image analysis and manual methods for tissue quantification in pancreatic carcinoma.

نویسندگان

  • A J Sims
  • M K Bennett
  • A Murray
چکیده

Objective measurements of tissue area during histological examination of carcinoma can yield valuable prognostic information. However, such measurements are not made routinely because the current manual approach is time consuming and subject to large statistical sampling error. In this paper, a semi-automated image analysis method for measuring tissue area in histological samples is applied to the measurement of stromal tissue, cell cytoplasm and lumen in samples of pancreatic carcinoma and compared with the standard manual point counting method. Histological samples from 26 cases of pancreatic carcinoma were stained using the sirius red, light-green method. Images from each sample were captured using two magnifications. Image segmentation based on colour cluster analysis was used to subdivide each image into representative colours which were classified manually into one of three tissue components. Area measurements made using this technique were compared to corresponding manual measurements and used to establish the comparative accuracy of the semi-automated image analysis technique, with a quality assurance study to measure the repeatability of the new technique. For both magnifications and for each tissue component, the quality assurance study showed that the semi-automated image analysis algorithm had better repeatability than its manual equivalent. No significant bias was detected between the measurement techniques for any of the comparisons made using the 26 cases of pancreatic carcinoma. The ratio of manual to semi-automatic repeatability errors varied from 2.0 to 3.6. Point counting would need to be increased to be between 400 and 1400 points to achieve the same repeatability as for the semi-automated technique. The results demonstrate that semi-automated image analysis is suitable for measuring tissue fractions in histological samples prepared with coloured stains and is a practical alternative to manual point counting.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quantification of diverse subcellular immunohistochemical markers with clinicobiological relevancies: validation of a new computer-assisted image analysis procedure.

Tissue microarray technology and immunohistochemical techniques have become a routine and indispensable tool for current anatomical pathology diagnosis. However, manual quantification by eye is relatively slow and subjective, and the use of digital image analysis software to extract information of immunostained specimens is an area of ongoing research, especially when the immunohistochemical si...

متن کامل

I-1: Screening of Subfertile Men for Testicularlar Carcinoma In Situ by An Automated Image Analysis-Based Cytological Test of The Ejaculate

Background: Testicular cancer (TC) is usually diagnosed after manifestation of an overt tumour. Tumour formation is preceded by a pre-invasive and asymptomatic stage, carcinoma in situ (CIS) testis, except for very rare subtypes. The CIS cells are located within seminiferous tubules but can be exfoliated and detected in ejaculates with specific CIS markers. Materials and Methods: We have built ...

متن کامل

Comparison between semi-automated segmentation and manual point-counting methods for quantitative analysis of histological sections.

The aim of the present study was to compare results obtained using the manual point-counting method with results obtained using the semi-automated segmentation method, in the quantitative evaluation of histological sections by light microscopy. The tongues of 40 rats (Ratus norvergicus) were processed using the paraffin technique, in which a 5-mum-thick tissue slice cut from each tongue is stai...

متن کامل

A Semi-Automated Algorithm for Segmentation of the Left Atrial Appendage Landing Zone: Application in Left Atrial Appendage Occlusion Procedures

Background: Mechanical occlusion of the Left atrial appendage (LAA) using a purpose-built device has emerged as an effective prophylactic treatment in patients with atrial fibrillation at risk of stroke and a contraindication for anticoagulation. A crucial step in procedural planning is the choice of the device size. This is currently based on the manual analysis of the “Device Landing Zone” fr...

متن کامل

Semi-quantitative segmental perfusion scoring in myocardial perfusion SPECT: visual vs. automated analysis

Introduction: It is recommended that the physician apply at least a semi-quantitative segmental scoring system in myocardial perfusion SPECT.  We aimed to assess the agreement between automated semi-quantitative analysis using QPS (quantitative Perfusion SPECT) software and visual approach for calculation of summed stress  score (SSS), summed rest score (SRS) and summed difference score (SDS). ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physics in medicine and biology

دوره 47 8  شماره 

صفحات  -

تاریخ انتشار 2002