Adhesion of thrombotic components to the surface of a clinically used oxygenator is not affected by Trillium coating.

نویسندگان

  • Jeanette M van den Goor
  • Willem van Oeveren
  • Peter M Rutten
  • Jan G Tijssen
  • León Eijsman
چکیده

The Trillium coating is designed to minimize adsorption of protein and the attachment of cells and other particles. The present study was undertaken to investigate the effect of surface coating on the adhesion of thrombotic components (activated platelets, white blood cells and fibrin) to the surface of a clinically used oxygenator. Twenty patients undergoing elective coronary artery bypass grafting (CABG) were randomized to one of the two oxygenator groups: non-coated (NC, n = 10) or Trillium-coated (TC, n = 10). Platelet and white blood cell counts and factor XIIa concentrations were determined prior to the induction of anesthesia and at the end of cardiopulmonary bypass (CPB). Binding of activated platelets, white blood cells and fibrin to the artificial surfaces was quantified by means of antibody binding and histological validation was achieved by scanning electron microscopy. Patient demographic and CPB data were similar for the two groups. No significant differences between the groups were found for any of the tested thrombotic components. However, observations from our scanning electron microscopy suggested a release of formed particles from the Trillium-coated surface. Primary adhesion of activated platelets, white blood cells and fibrin to the artificial surface of the venous blood inlet from an oxygenator is not affected by the Trillium surface coating under conditions of full systemic heparinization.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Trillium-coated oxygenators in adult open-heart surgery: a prospective randomized trial.

This randomized, prospective clinical trial examines the impact of the use of Trillium biopassive surface coating on clinical outcomes after cardiopulmonary bypass (CPB) that may be induced by contact of blood elements with foreign surfaces. The study consisted of 98 consecutive patients randomly assigned to either a CPB circuit that consisted of a Trillium-coated Affinity open reservoir oxygen...

متن کامل

Roughness Model for Adhesion Testing of Pharmaceutical Coating Materials

Objective Roughness is the main parameter in interlocking bonding mechanism. Yet there is no model designed to evaluate the effect of surface roughness on adhesion of coating materials in pharmaceutical sciences. Materials and Methods In this study polymethyl metacrylate spherical beads with different sizes were poured into 10 mm mold, then it was pressed by hand screw and finally heated to 141...

متن کامل

Extended support with the Terumo Baby-RX oxygenator.

The Terumo Baby-RX, a new-generation low prime oxygenator, recently has entered the perfusion market in North America. This oxygenator is designed exclusively for neonates and infants and has the smallest priming volume of any clinically available oxygenator. The BABY-RX also is treated with X Coating, Terumo's biocompatible, hydrophilic polymer surface coating that reduces platelet adhesion an...

متن کامل

The effects of heparin coating of oxygenator fibers on platelet adhesion and protein adsorption.

UNLABELLED Platelet adhesion on the cardiopulmonary bypass oxygenator membrane is associated with impaired hemostasis. We investigated the effects of heparin coating of the oxygenator membrane on protein adsorption and platelet adhesion on the surface. Noncoated and heparin-coated polypropylene membranes were incubated in whole blood with small- (1 U/mL) or large-dose (5 U/mL) heparin as an ant...

متن کامل

Grafting of Maleic Anhydride onto Co)propylene-b-ethylene( by Extrusion Process: Measurement of Adhesion to Steel Surface

Polypropylene (PP) has poor adhesion to metals and other surfaces for its chemical structure. Hence, chemical modification of PP is necessary for metal surface coating application. In this research, grafting of maleic anhydride (MA) onto co(propylene-b-ethylene) in the presence of a dicumyl peroxide (DCP) was accomplished in a single screw extruder. Characteristics of the modified polymer were ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Perfusion

دوره 21 3  شماره 

صفحات  -

تاریخ انتشار 2006