A Comparison of the Fixation Strengths Provided by Different Intraosseous Tendon Lengths during Anterior Cruciate Ligament Reconstruction: A Biomechanical Study in a Porcine Tibial Model

نویسندگان

  • Dong-Lyul Yang
  • Sang-Ho Cheon
  • Chang-Wug Oh
  • Hee-Soo Kyung
چکیده

BACKGROUND The purpose of this study was to determine the tibial fixation strength provided by different intraosseous soft tissue graft lengths within the tibial tunnel. METHODS Porcine tibial bones and digital flexor tendons were used for testing. Bone mineral densities of proximal tibial medial condyles were measured, and two-strand tendon bundles of 8 mm diameter were used. An intraosseous graft length of 2 cm was used in group 1 (n = 10), and a graft length of 4 cm was used in group 2 (n = 10). Tunnels were 4 cm in length and 8 mm in diameter. Tibial fixation was performed using a suture tied around a screw post with a washer and an additionally inserted 7 × 20 mm bioabsorbable screw. After applying preconditioning loading of 10 cycles, 1,000 cycles between 70-220 N were applied at a frequency of 1 Hz. Graft slippage and total graft movement were recorded. Ultimate tensile strength was measured by pull-out testing at an Instron crosshead speed of 1,000 mm/min. RESULTS No significant intergroup difference was found for total graft movement after cyclic loading (slippage in group 1, 1.2 mm and group 2, 1.2 mm, respectively, p = 0.917; and total graft movement in group 1, 3.3 mm and group 2, 2.7 mm, respectively, p = 0.199). However, mean ultimate tensile strength in group 2 was significantly higher than that in group 1 (group 1, 649.9 N; group 2, 938 N; p = 0.008). CONCLUSIONS In a porcine model, ultimate tensile strength was greater for a 4 cm long intraosseous flexor tendon in the tibial tunnel. However, no intergroup difference in graft slippage or total graft movement was observed. The results show that a 2 cm intraosseous graft length in the tibial tunnel is safe and has sufficient strength (> 450 N) for adequate rehabilitation after anterior cruciate ligament reconstruction.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Biomechanical Comparison Between Bashti Bone Plug Technique and Biodegradable Screw for Fixation of Grafts in Ligament surgery

  Background: Ligament reconstruction is a common procedure in orthopedic surgery. Although several popular techniques are currently in use, new methods are proposed for secure fixation of the tendon graft into the bone tunnel. Purposes: We sought to introduce our new technique of Bashti bone plug for fixation of soft tissue graft in anterior cruciate ligament (ACL) reconstruction and to compar...

متن کامل

Tibial fixation of anterior cruciate ligament allograft tendons: comparison of 1-, 2-, and 4-stranded constructs.

BACKGROUND In sum, 1-, 2-, and 4-stranded allografts are used for soft tissue anterior cruciate ligament reconstruction; however, the fixation properties of fixation devices are not well assessed. HYPOTHESIS There are no differences in the biomechanical characteristics of 1 (Achilles)-, 2 (posterior tibialis)-, and 4 (semitendinosus)-stranded allograft tibial fixation. STUDY DESIGN Controll...

متن کامل

Biomechanical comparison of hamstring and patellar tendon graft anterior cruciate ligament reconstruction techniques: The impact of fixation level and fixation method under cyclic loading.

PURPOSE To mechanically test different reconstruction techniques of the anterior cruciate ligament (ACL) under incremental cyclic loading and to evaluate the impact of the level and method of graft fixation on tensile properties of each technique. TYPE OF STUDY In vitro biomechanical study. METHODS Four hamstring and 1 patellar tendon reconstruction techniques were performed on 40 young to ...

متن کامل

The fixation strength of six hamstring tendon graft fixation devices in anterior cruciate ligament reconstruction. Part II: tibial site.

BACKGROUND Tibial fixation is more problematic than femoral fixation in anterior cruciate ligament reconstruction. HYPOTHESIS There is no difference in initial fixation strength among hamstring tendon graft tibial fixation devices. STUDY DESIGN Randomized experimental study. METHODS Each of six devices used to fix 120 quadrupled human semitendinosus-gracilis tendon grafts into porcine tib...

متن کامل

Functional Outcome Following Arthroscopic ACL Reconstruction with Rigid Fix: A Retrospective Observational Study

  Background: No uniform consensus exists to decide type of fixation for arthroscopic anterior cruciate ligament reconstruction. Hypothsis: There is similar functional outcome after rigid fix compared to other methods of fixation which has been published. Study design: Retrospective observational study. Methods: A total of 50 patients underwent arthroscopic anterior cruciate ligament reconstruc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2014