The relationship between inferior vena cava diameter measured by bedside ultrasonography and central venous pressure value

نویسندگان

  • Serenat Citilcioglu
  • Ahmet Sebe
  • Mehmet Oguzhan Ay
  • Ferhat Icme
  • Akkan Avci
  • Muge Gulen
  • Mustafa Sahan
  • Salim Satar
چکیده

OBJECTIVE We aimed to present inferior vena cava (IVC) diameter as a guiding method for detection of relationship between IVC diameter measured noninvasively with the help of ultrasonography (USG) and central venous pressure (CVP) and evaluation of patient's intravascular volume status. METHODS Patients over the age of 18, to whom a central venous catheter was inserted to their subclavian vein or internal jugular vein were included in our study. IVC diameter measurements were recorded in millimeters following measurement by the same clinician with the help of USG both at the end-inspiratory and end-expiratory phase. CVP measurements were viewed on the monitor by means of piezoelectric transducer and recorded in mmHg. SPSS 18.0 package program was used for statistical analysis of data. RESULTS Forty five patients were included in the study. The patients had the diagnosis of malignancy (35.6%), sepsis (13.3%), pneumonia, asthma, chronic obstructive pulmonary disease (11.1%). 11 patients (24.4%) required mechanical ventilation while 34 (75.6%) patients had spontaneous respiration. In patients with spontaneous respiration, a significant relationship was found between IVC diameters measured by ultrasonography at the end of expiratory and inspiratory phases and measured CVP values at the same phases (for expiratory p = 0.002, for inspiratory p= 0.001). There was no statistically significant association between IVC diameters measured by ultrasonography at the end of expiration and inspiration and measured CVP values at the same phases in mechanically ventilated patients. CONCLUSIONS IVC diameter measured by bedside ultrasonography can be used for determination of the intravascular volume status of the patients with spontaneous respiration.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Emergency department bedside ultrasonographic measurement of the caval index for noninvasive determination of low central venous pressure.

STUDY OBJECTIVE Among adult emergency department (ED) patients undergoing central venous catheterization, we determine whether a greater than or equal to 50% decrease in inferior vena cava diameter is associated with a central venous pressure of less than 8 mm Hg. METHODS Adult patients undergoing central venous catheterization were enrolled in a prospective, observational study. Inferior ven...

متن کامل

The efficacy of inferior vena cava diameters and the jugular vein in assessing fluid resuscitation

Objective: Fluid resuscitation is necessary in almost all critical patients. The central venous pressure (CVP) is a well-established method of assessing resuscitation. Recently, there have been attempts to investigate less invasive methods like the diameters of inferior vena cava (IVC) or the jugular vein. We aimed to investigate this method in our research.Methods: Seventy eight critical...

متن کامل

A Non-invasive Method for Assessment of Intravascular Fluid Status: Inferior Vena Cava Diameters and Collapsibility Index

OBJECTIVE To evaluate the correlation between central venous pressure (CVP) and inferior vena cava (IVC) diameters measured by ultrasonography (Ultrasound) in critically ill patients. METHODS Intubated critically ill patients were enrolled. The CVP values were measured using a U-tube manometer and were compared to the IVC diameters and collapsibility index, which were measured by bedside Ultr...

متن کامل

Internal Jugular Vein Height and Inferior Vena Cava Diameter Measurement using Ultrasound to Determine Central Venous Pressure: A Correlation Study.

OBJECTIVE To determine the correlation between central venous pressure (CVP) measured by conventional central venous access and ultrasonographic measurement of internal jugular vein (IJV) height and inferior vena cava (IVC) diameter. METHODS A prospective, cross-sectional, convenience sampling observational study. RESULTS 25 patients from the Emergency Department (ED) Universiti Kebangsaan ...

متن کامل

بررسی ارزش تشخیصی میزانCaval index در تعیین فشار ورید مرکزی پایین در مقایسه با روش تهاجمی در بیماران بستری در ICU بیمارستان شهید باهنر کرمان

Introduction: Measurement of central venous pressure can be regarded as a beneficial guide in order to assess a patient's hemodynamic status, specifically in patient with sever sepsis and septic shock, for whom a central venous pressure of less than 8mmhg is considered as an indicator for aggressive intravenous fluid replacement. Therefore, this study aimed to investigate the ultrasonographic e...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 30  شماره 

صفحات  -

تاریخ انتشار 2014