Minimally invasive optical beam profiler.

نویسندگان

  • Nabeel Riza
  • Doug Jorgesen
چکیده

Proposed and demonstrated is a minimally invasive optical beam profiler using a non-pixelated liquid crystal spatial light modulator. The profiler features high detection sensitivity in the visible band, high 50 lines/mm spatial resolution, beam observation zone 100 % fill factor and magnification flexibility, and video rate operations. Applications for this beam profiler includes plug and test beam measurements with minimal interruptions and feedback effects introduced into the optical beam system under test.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

6th Asian Congress of Endometriosis and 6th International Congress of Minimally Invasive Surgery

6th Asian Congress of Endometriosis and 6th International Congress of Minimally Invasive Surgery

متن کامل

4th International Congress of Minimally Invasive Surgery-IRAN

4th International Congress of Minimally Invasive Surgery-IRAN

متن کامل

The Body Image Dissatisfaction and Psychological Symptoms among Invasive and Minimally Invasive Aesthetic Surgery Patients

BACKGROUND Elective aesthetic surgeries are increasing in the Iranian population with reasons linked to body image dissatisfaction and psychological symptoms. This study compared the body image dissatisfaction and psychological symptoms among invasive and minimally invasive aesthetic surgery patients and a control group. METHODS Data from 90 participants (invasive aesthetic surgery=30 ...

متن کامل

Minimally Invasive Surgical Approach to Distal Fibula Fractures: A Technique Tip

  Wound complications following ankle fracture surgery are a major concern. Through the use of minimally invasive surgical techniques some of these complications can be mitigated. Recent investigations have reported on percutaneous fixation of distal fibula fractures demonstrating similar radiographic and functional outcomes to traditional open approaches. The purpose of this manuscript is to ...

متن کامل

Air Convection Noise of Pencil-beam Interferometer for Long Trace Profiler

In this work, we investigate the effect of air convection on laser-beam pointing noise essential for the long trace profiler (LTP). We describe this pointing error with noise power density (NPD) frequency distributions. It is shown that the NPD spectra due to air convection have a very characteristic form. In the range of frequencies from ~0.05 Hz to ~0.5 Hz, the spectra can be modeled with an ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Optics express

دوره 12 9  شماره 

صفحات  -

تاریخ انتشار 2004