Comparison of Hydroxyapatite-coated stems in total hip arthroplasty after a minimum 10-years follow-up.

نویسندگان

  • J Gallo
  • I Landor
  • I Cechová
  • D Jahoda
چکیده

PURPOSE OF THE STUDY Hydroxypatite coating (HAC) was introduced into total hip arthroplasty (THA) practice to improve the fixation interface between bone and prosthesis. To test this assumption however, long-term follow-up investigations are needed. In this study, we present data for two consecutive series of THA stems with HAC and a minimum ten-year follow-up. MATERIAL Overall, 249 patients (271 hips) were included in the study, of these 122 (135 hips) had Walter hip arthroplasty (WHA group) with a two-layered TiO2/HAC at the proximal part of the stem and 127 (136 hips) had ABG I prostheses (ABG I group) with a single-layered HAC at the proximal part of the stem. Mean length of follow-up was 11.4 years (0.8-13) and 9.8 years (4-12) in WHA and ABG I groups, respectively. Mean age at the time of surgery was 62 years (23-79) and 47 years (21-65) in WHA and ABG I groups, respectively. METHODS Probabilities of implant survival were estimated using the Kaplan-Meier method. Radiographic data were included to construct the worst-case scenario. Differences in survival curves were evaluated by Gehan's Wilcoxon test. Harris hip score was used to compare preoperative status with that of final follow-up. RESULTS The overall survival of WHA was significantly better than the ABG I (0.85 versus 0.66; p < 0.05). The main reason for a high revision rate in ABG I was periprosthetic osteolysis followed by aseptic loosening. With regard to stems, the survivorship curve for the Walter stem was significantly better than for the ABG I stem even when radiographic results were included (p = 0.0002). In the WHA group, two stems (1.5%) were revised due to sepsis, in contrast to thirty-one stems (23.5%) revised in the ABG I group due to osteolysis and aseptic loosening (p < 0.05). Significant improvement was achieved in both groups under study in terms of Harris hip score. DISCUSSION Data presented here appear surprising at first glance because the differences between the stems under study are only minor. The failure in ABG I was most probably caused by poor polyethylene quality and poor locking mechanism of polyethylene liner in the metallic shell. In addition, HAC used in ABG I prosthesis was not able to prevent the development of polyethylene disease stimulated by high wear rate. CONCLUSION This study revealed excellent survivorship for WHA stems after a minimum ten-year survival and significantly poorer survivorship for the ABG I stems.This may be explained at least particularly by combined two-layered HAC used in WHA stems which provide simultaneously endurable bone interlocking and effective barrier against expansion of polyethylene disease.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Effect of Hydroxyapatite Coating on Long-term Results of Total Hip Arthroplasty with Hydroxyapatite-coated Anatomic Femoral Stem

PURPOSE To evaluate the clinical and radiological results, as well as the survival rate, associated with total hip arthroplasty using a hydroxyapatite (HA)-coated anatomical femoral stem at a follow-up of ≥12 years. MATERIALS AND METHODS From April 1992 to May 1997, 86 patients (102 hips) underwent total hip arthroplasty with a HA-coated ABG I (Anatomical Benoist Giraud; Howmedica) hip prosth...

متن کامل

Bone density study of the proximal femur after hip arthroplasty with porous-coated implants

Progressive loss of bone mineral density around the femora! component of total hip replacement continues to pose a threat to long term prosthetic survival. A linear study was undertaken to measure bone mineral density on a monthly basis following total hip arthroplasty in 11 male patients. The opposite femur was used as the control measurement. Bone mineral density was unchanged at two mo...

متن کامل

Seven-year Results of a Tapered, Titanium, Hydroxyapatite-Coated Cementless Femoral Stem in Primary Total Hip Arthroplasty

BACKGROUND Aseptic loosening of cemented hip prostheses is recognized as a long-term problem, and especially in males and younger patients. Much energy has been focused on developing new prostheses that are designed for cementless fixation. We evaluated the performance of and periprosthetic bone response to a tapered, titanium, hydroxyapatite (HA)-coated femoral hip prosthesis at a minimum of 7...

متن کامل

A prospective randomized study comparing electrochemically deposited hydroxyapatite and plasma-sprayed hydroxyapatite on titanium stems

BACKGROUND AND PURPOSE Plasma-sprayed hydroxyapatite (HA) is a successful coating for fixation of uncemented femoral stems. There may be alternative coatings with advantages in bone remodeling and transport of bone-active substances. We investigated whether an electrochemically deposited hydroxyapatite, Bonemaster (BM), might be a safe alternative in total hip arthroplasty. Our hypothesis was t...

متن کامل

Results of a hydroxyapatite-coated femoral stem (Corail) in Chinese: a minimum 10-year follow-up

BACKGROUND Due to the adverse effects of cemented hip arthroplasty, uncemented stems with hydroxyapatite (HA) coating reduces these risks and enhanced integration. The concept of an extensive HA coating for the fixation of a tapered femoral stem (Corail®) was introduced, which can achieve durable biological fixation and preserve normal periprosthetic bone activity. Here we describe the clinical...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Acta chirurgiae orthopaedicae et traumatologiae Cechoslovaca

دوره 75 5  شماره 

صفحات  -

تاریخ انتشار 2008