Stability Indicating Rp-hplc-pda Method for Determination of Abiraterone Acetate and Characterization of Its Base Catalyzed Degradation Product by Lc-ms
ثبت نشده
چکیده
Objective: The present work describes stability indicating (SI) RP-HPLC-PDA method for determination of abiraterone acetate (ABA) and characterization of its base catalyzed degradation product by LC-MS. Methods: The separation was achieved by using column Kromasil C18 Results: The retention time of ABA was 5.4±0.01 min. Linearity was found to be in the range of 5–30 μg/ml. The limit of detection and quantitation were 0.25 μg/ml and 0.75 μg/ml respectively, and percentage recovery of ABA was found to be 99.52 to 100.13 %. Mass spectral data of base degraded product of ABA shows a prominent molecular ion peak at m/z-391.5. Major fragmentation leads to formation of 10–Methyl 2,3,4,7,8,9,10,11,12,13,14,15-dodecanhydro-1H cyclopenta (α)phenanthren-3-ol as a degradant (D (250 mm × 4.6 mm, 4.0 μ) using acetonitrile (ACN): ammonium acetate buffer 10 mM, pH adjusted to 3.5 with acetic acid (AA) in the ratio of 10:90 % v/v as eluent. The Mobile phase flow rate was 0.6 ml/min and data integration was achieved at 235 nm. 2) at m/z-257.81, due to corresponding loss of C8H12 Conclusion: The results of the various validation studies showed that the LC method is fast, specific, accurate, reproducible, possessed significant linearity and precision. The drug was found to be stable under all the stress conditions except basic stress. Thus developed method reported first time is novel with a very short run time of 6 min. ON. All the analytical validation parameters were determined and found in the limit as per ICH guidelines.
منابع مشابه
Forced Degradation Behaviour of Fluphenazine Hydrochloride by LC and Characterization of its Oxidative Degradation Product by LC–MS/MS
A novel, stability-indicating high-performance liquid chromatographic (HPLC) method is delivered for the determination of fluphenazine hydrochloride (FPZ) and its degradation products. The forced degradation testing of FPZ was carried out for hydrolytic, oxidative, photolytic, and thermal degradation. The degradation appeared using a reversed-phase C18 column at ambient temperature with a mobil...
متن کاملDevelopment of a Stability-Indicating RP-HPLC Method for the Determination of Rupatadine and its Degradation Products in Solid Oral Dosage Form
A simple, sensitive, and reproducible reversed-phase high-performance liquid chromatography (RP-HPLC) method, coupled with a photodiode array detector, was developed for the determination of rupatadine (RUPA) and its related substances in pharmaceutical dosage forms. Chromatographic separation was achieved on the Hypersil BDS (150 x 4.6 mm, 5 μm) column with a mobile phase containing a gradient...
متن کاملA Validated Stability-Indicating LC Method for Fluocinonide in the Presence of Degradation Products, Its Process-Related Impurities and Identification of Degradation Products
The objective of the current study was to develop a validated, specific and stability-indicating reverse phase liquid chromatographic method for the quantitative determination of fluocinonide and its related substances. The determination was done for active pharmaceutical ingredient and its pharmaceutical dosage forms in the presence of degradation products, and its process-related impurities. ...
متن کاملDevelopment and validation of a fast, simple and specific stability indicating RP-HPLC method for determination of Dexpanthenol in eye gel formulation.
AIn this study a simple and reliable stability-indicating RP-HPLC method was developed and validated for analysis of Dexpanthenol in an artificial tear formulation. The chromatographic separation was performed on a HPLC C18 column (25.0 cm 4.6 mm, 5 m) using a mixture of 0.037 M monobasic potassium phosphate in water (adjusted with 0.1% (v/v) phosphoric acid to a pH of 3.2) and methanol (90:...
متن کاملDevelopment and validation of a fast, simple and specific stability indicating RP-HPLC method for determination of Dexpanthenol in eye gel formulation.
AIn this study a simple and reliable stability-indicating RP-HPLC method was developed and validated for analysis of Dexpanthenol in an artificial tear formulation. The chromatographic separation was performed on a HPLC C18 column (25.0 cm 4.6 mm, 5 m) using a mixture of 0.037 M monobasic potassium phosphate in water (adjusted with 0.1% (v/v) phosphoric acid to a pH of 3.2) and methanol (90:...
متن کامل