Automated peritoneal dialysis prescriptions for enhancing sodium and fluid removal: a predictive analysis of optimized, patient-specific dwell times for the day period.

نویسندگان

  • Alp Akonur
  • Steven Guest
  • James A Sloand
  • John K Leypoldt
چکیده

BACKGROUND Remaining edema-free is a challenge for many automated peritoneal dialysis (APD) patients, especially those with fast ("high") transport characteristics. Although increased use of peritoneal dialysis (PD) solutions with high glucose concentrations may improve volume control, frequent use of such solutions is undesirable. METHODS We used the 3-pore kinetic model to evaluate 4 alternative therapy prescriptions for the APD day exchange in anuric patients with high, high-average, and low-average transport characteristics. Four prescriptions were modeled: Therapy 1: Optimal, individualized dwell times with a dry period. Therapy 2: Use of a midday exchange. Therapy 3: Use of an icodextrin-containing dialysate during a 14-hour dwell. Therapy 4: Use of optimal, individualized dwell times, followed by an icodextrin dwell to complete the daytime period. The alternative therapies were compared with a reference standard therapy using glucose solution during a 14-hour dwell. The nighttime prescription was identical in all cases (10 L over 10 hours), and all glucose solutions contained 2.27% glucose. Net ultrafiltration (UF), sodium removal (NaR), total carbohydrate (CHO) absorption, and weekly urea Kt/V for a 24-hour period were computed and compared. RESULTS The UF and NaR were substantially higher with therapy 1 than with standard therapy (1034 mL vs 621 mL and 96 mmol vs 51 mmol respectively), without significant changes in CHO absorption or urea Kt/V. However, therapy 1 resulted in reduced β2-microglobulin clearance (0.74 mL/min vs 0.89 mL/min with standard therapy). Compared with therapy 1, therapy 2 improved UF and NaR (1062 mL vs 1034 mL and 99 mmol vs 96 mmol); however, that improvement is likely not clinically significant. Therapy 2 also resulted in a higher Kt/V (2.07 vs 1.72), but at the expense of higher glucose absorption (difference: 42 g). The UF and NaR were highest with a long icodextrin-containing daytime dwell either preceded by a short optimized dwell (1426 mL and 155 mmol) or without such a dwell (1327 mL and 148 mmol). CONCLUSIONS The 3-pore model predictions revealed that patient-specific optimal dwell times and regimens with a longer day dwell might provide improved UF and NaR options in APD patients with a variety of peritoneal membrane transport characteristics. In patients without access to icodextrin, therapy 1 might enhance UF and NaR and provide a short-term option to increase fluid removal. Although that approach may offer clinicians a therapeutic option for the overhydrated patient who requires increased UF in the short term, APD prescriptions including icodextrin provide a means to augment sodium and fluid removal. Data from clinical trials are needed to confirm the predictions from this study.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Adapted automated peritoneal dialysis.

Conventional automated peritoneal dialysis (APD) is prescribed as a repetition of the same dwell time and the same fill volume delivered by the cycler during the dialysis session. Nevertheless, it is well recognized that a cycle with a short dwell time and a small fill volume favors ultrafiltration (UF), while a cycle with a long dwell time and a large fill volume favors uremic toxin removal. T...

متن کامل

Sodium removal in peritoneal dialysis: the role of icodextrin and peritoneal dialysis modalities.

One of the main goals of dialysis is the control of extracellular volume, because inadequate sodium and fluid removal result in fluid overload and increased mortality. In the present study, we evaluated the roles of continuous ambulatory peritoneal dialysis (CAPD), continuous cycling peritoneal dialysis (CCPD), and the use of icodextrin on sodium removal in 29 patients (n = 18 on CAPD, n = 11 o...

متن کامل

Peritoneal dialysis fluid concentrations of linezolid in the treatment of vancomycin-resistant Enterococcus faecium peritonitis.

OBJECTIVE To determine linezolid concentrations in peritoneal dialysis fluid after multiple oral doses of the drug in a 46-year-old man with vancomycin-resistant Enterococcus faecium peritonitis who was undergoing peritoneal dialysis. METHODS After administration of oral linezolid 600 mg twice/day was started, peritoneal dialysis fluid was collected at the end of several 4- and 8-hour dwell t...

متن کامل

Determinants of sodium removal with tidal automated peritoneal dialysis.

In a comprehensive evaluation of dialysis adequacy, major attention has been recently paid to fluid and Na balance. Removal of Na has been reported to be significantly poorer with automated peritoneal dialysis (APD) than with continuous ambulatory peritoneal dialysis. Only limited data on Na removal with tidal APD have been published. We analyzed peritoneal Na mass balance in 122 separate night...

متن کامل

Ultrafiltration efficiency during automated peritoneal dialysis using glucose-based solutions.

The ultrafiltration (UF) efficiency of peritoneal dialysis (PD) solutions, defined as the net UF divided by the amount of carbohydrate absorbed per dwell, has been shown to be higher during long dwells with 7.5% icodextrin solution (Extraneal: Baxter Healthcare Corporation, Deerfield, IL, U.S.A.) than during those with glucose-based solution (2.5% and 4.25% Dianeal: Baxter Healthcare Corporatio...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Peritoneal dialysis international : journal of the International Society for Peritoneal Dialysis

دوره 33 6  شماره 

صفحات  -

تاریخ انتشار 2013